Integrator’s look at the S8VK-G24048 power supply
It accepts 47 to 63 Hz mains, with a peak inrush current of 32 A under cold start — worth noting for branch-circuit fuse or breaker sizing to avoid nuisance trips. Minimum hold-up time is 43 ms at full load, which keeps the downstream DC bus alive through a few lost line cycles; startup time reaches nominal output within 380 ms maximum. Output noise is specified at 350 mV maximum, so sensitive analog loads may warrant additional post-filtering; the supply includes overload, overvoltage, and automatic reset protection as built-in features.
Mounting and wiring notes
Mounts on DIN rail (IP20 rating, metal case). Dimensions: 5.91 x 2.36 x 4.92 inches. Screw terminals accept 20 to 10 AWG wire. Torque settings are not provided; refer to the installation sheet. A green LED indicates output present; parallel capability is listed, so multiple units can be wired for current sharing if more than 5 A is needed — verify the paralleling set in the manual.
Compliance and sourcing posture
The S8VK-G24048 carries CE, CSA C22.2 No. 107.1/62368-1, cULus, cURus, EN50178, EN61558-2-16, EN62368-1, Lloyd’s Standards EN60204-1 PELV, and UL 508/62368-1 — a wide certification set that covers industrial, lab, and marine applications.