140DDO35310C key specifications
ParameterValue
Protection typeInternal output protection by 5 A fuse per group
Range of productModicon Quantum automation platform
Product or component typeDc discrete output module
Maximum voltage drop<0.4 V 0.5 A
Output voltage limits19.2...30 V
Discrete output voltage24 V DC
Surge current5 A 1 ms
Maximum load current16 A per module 4 A per group
Bus current requirement330 mA
Maximum leakage current0.4 mA 30 V
Power dissipation2.0 W + (0.4 V x total load current)
Response time<= 1 ms at state 1 to state 0

All specifications

140DDO35310C additional specifications
ParameterValue
Relative humidity95 % without condensation
Operating altitude<= 16404.2 ft (5000 m)
StandardsCSA C22.2 No 142 UL 508
MarkingCE
Category18155-QUANTUM I/O & POWER SUPPLIES
Module formatStandard
Load inductanceInductance(H) = 0.5/((current(A))² x (switching frequency(Hz)))
Fault indicationLoss of field power Blown fuse
Local signalling1 LED (green) for bus communication is present (Active) 1 LED (red) for external fault detected (F) 32 LEDs (green) for input status
Group of channels4 groups of 8
Protective treatmentConformal coating Humiseal 1A33
Discrete output logicNegative logic (sink)
Maximum tungsten load12 W 24 V
Addressing requirement2 output words
Associated fuse rating3 A each point 5 A per group
Discrete output number32
Absolute maximum output50 V 1 s decaying pulse
Isolation between group500 Vrms DC for 1 minute
Isolation between channels and bus1780 Vrms DC for 1 minute
Ambient air temperature for storage-40...185 °F (-40...85 °C)
Resistance to electromagnetic fields9.1 V/m (10 V/m) 80...2000 MHz IEC 801-3
Ambient air temperature for operation32...140 °F (0...60 °C)
Resistance to electrostatic discharge4 kV contact IEC 801-2 8 kV on air IEC 801-2