Schneider Electric A9D02806 — Residual Current Breakers (RCCB/RCBO)

A9D02806 Acti9 iC60H RCBO, 6A C-curve, 30mA, 10kA

MPNA9D02806
Active

Schneider Electric Acti9 iC60H RCBO, A9D02806, 1P+Ns, 6A C-curve, 30mA earth leakage, 10kA Icn at 240V AC, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D02806 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D02806 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D02806 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D02806 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D02806 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D02806 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It protects a 1P+Ns circuit at 6 A rated current (C-curve, thermal-magnetic trip) with integrated 30 mA earth-leakage protection. Clip-on DIN rail mounting, 2 module pitches (18 mm wide, 77.5 mm deep, 110 mm high). IP20 enclosure, IP40 inside a modular enclosure.

Limitation class 3 reduces let-through energy. The RCBO integrates both overcurrent and earth-leakage protection in one unit, saving one module width versus a separate MCB + RCCB pair. At 18 mm per pole, an 18-way distribution board fits 18 RCBOs plus a main switch — no extra width for the RCD element.

Depth of 77.5 mm fits within a 100 mm deep enclosure with clearance for wiring — no deep-can enclosure required. The 45 mm grid distance aligns with standard busbar systems. Screw-clamp terminals: top accepts 1–25 mm² rigid, bottom 1–16 mm² rigid. Tightening torque 3.5 N.m top, 2 N.m bottom. Wire strip length 14 mm top, 13 mm bottom. The 2 N.m bottom torque is lower than typical — use a torque screwdriver to avoid crushing fine-stranded conductors. Padlockable with a 4 mm padlock for lockout/tagout. ON/OFF indication visible through the enclosure window. The toggle control provides clear visual confirmation of contact position.

Frequently asked questions

What compliance documentation does the A9D02806 carry?

The A9D02806 is certified to IEC 61009-1 and IEC 61009-2-2 (residual current operated circuit-breakers with integral overcurrent protection). It is designed for TN earthing systems and carries IP20 (IP40 in modular enclosure) protection. The part is RoHS and REACH compliant as standard for Schneider Electric Acti9 products.