Skip to main content
Schneider Electric A9D02820 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D02820 Acti9 iC60 RCBO, 20 A, 30 mA, 10

MPNA9D02820
Active

Schneider Electric Acti9 iC60H RCBO, 1P+Ns, 20 A rated current, 30 mA earth leakage sensitivity, C-curve, 10 kA breaking capacity at 240 V AC, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D02820 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D02820 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D02820 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D02820 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D02820 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D02820 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It protects a single outgoing circuit against both overload/short-circuit (thermal-magnetic trip, C-curve) and earth leakage (30 mA sensitivity), all in one DIN-rail unit that clips onto the standard 45 mm grid. Rated at 20 A at 50 °C, it handles typical lighting, socket outlet, and small appliance circuits in TN earthing systems. The 10 kA Icn breaking capacity at 240 V AC (50/60 Hz) means it can safely interrupt a fault current up to that level — sufficient for most residential and light commercial distribution boards where the prospective short-circuit current stays under 10 kA. Limitation class 3 (energy-limiting) means it restricts let-through energy on short-circuits, which helps with downstream device coordination.

At 18 mm wide (2 x 9 mm pitches) and 77.5 mm deep, it fits a standard distribution board without protruding beyond the enclosure depth. Height is 110 mm. IP20 rated, with IP40 in a modular enclosure — fine for dry indoor panels. Padlockable with a Ø 4 mm padlock for lockout/tagout during maintenance. ON/OFF indication is local on the toggle.

Compliance documentation is straightforward: the RCBO is certified to IEC 61009-1 and IEC 61009-2-2, the governing standards for combined RCD/MCBs. The white finish and tropicalisation class 2 suit moderate indoor environments up to 55 °C and 95% relative humidity.

Frequently asked questions

What is the breaking capacity of A9D02820?

10,000 A Icn at 240 V AC, 50/60 Hz.

What earth leakage sensitivity does A9D02820 have?

30 mA, integrated into the RCBO.

What is the rated current of A9D02820?

20 A at 50 °C.

Where can I buy A9D02820 and how is it quoted?

The A9D02820 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance standards does A9D02820 meet?

IEC 61009-1 and IEC 61009-2-2 for combined RCD/MCBs.

MPN
A9D02820