Schneider Electric A9D02825 Acti9 iC60 RCBO, 25 A, 10 kA, 30

MPNA9D02825
Obsolete

Schneider Electric Acti9 iC60H RCBO, A9D02825, 1P+N, C-curve, 25 A rated, 10 kA breaking capacity, 30 mA earth-leakage, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D02825 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D02825 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D02825 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D02825 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D02825 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D02825 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It integrates a 25 A thermal-magnetic MCB (C-curve) and a 30 mA earth-leakage detector in one clip-on DIN-rail unit, saving a full module width versus separate devices. Earth-leakage protection is integrated at 30 mA sensitivity, providing supplementary protection against direct contact and covering the typical requirement for socket-outlet circuits in TN earthing systems. The neutral is switched (1P+N) with the neutral on the left side of the module.

The 18 mm width occupies 2 x 9 mm pitches. Top and bottom screw-clamp terminals accept 1…25 mm² rigid (top) and 1…16 mm² rigid (bottom); tightening torque is 3.5 N·m top, 2 N·m bottom. IP20 finger-safe, IP40 in a modular enclosure. Padlockable with a Ø 4 mm padlock for lockout/tagout. The toggle provides ON/OFF local indication. Wire stripping length is 13 mm (bottom) and 14 mm (top).

Designed and certified to IEC 61009-1 and IEC 61009-2-2, the international standard for RCBOs. Limitation class 3 indicates energy-limiting performance that reduces let-through energy on short-circuit. Suitability for isolation is confirmed. Southeast Asia, coastal plant rooms).

MPN