Skip to main content
Schneider Electric A9D02832 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D02832 Acti9 iC60 RCBO, 32A C-curve 30m

MPNA9D02832
Active

Schneider Electric Acti9 iC60 RCBO, 1P + Ns, 32 A, C-curve, 30 mA earth leakage, 10 kA Icn, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D02832 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D02832 — Electrical Ratings
ParameterValue
Rated current (In)32 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D02832 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D02832 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D02832 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D02832 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

This is the thermal-magnetic version, clip-on for DIN rail, intended for outgoing circuits in TN earthing systems.

The 30 mA earth-leakage sensitivity provides personal protection against indirect contact; it's the standard threshold for socket-outlet circuits in most domestic and light commercial installations.

Clip-on mounting onto a 45 mm grid DIN rail — standard for any 35 mm DIN rail enclosure. The device occupies 2 x 9 mm pitches, so 18 mm width. Neutral is on the left. Wire stripping length is 13 mm for bottom, 14 mm for top.

The A9D02832 is certified to IEC 61009-1 and IEC 61009-2-2, the international standards for RCBOs. The device is tropicalised to class 2, which means it's treated against humidity and fungal growth for use in tropical climates. It's padlockable with a 4 mm padlock for lockout/tagout.

Frequently asked questions

What is A9D02832's listed depth?

The depth is 77.5 mm, width 18 mm, height 110 mm.

What is the A9D02832 used for?

It's a 1P + Ns RCBO for outgoing circuits in TN earthing systems, providing both overcurrent protection (thermal-magnetic, 32 A, C-curve) and earth-leakage protection (30 mA) in a single DIN-rail module.

What compliance documentation does Schneider provide for A9D02832?

The device is certified to IEC 61009-1 and IEC 61009-2-2. Standard Schneider documentation includes the Declaration of Conformity and test certificates per these standards; consult your Schneider contact for specific RoHS/REACH declarations.

Where can I buy the A9D02832?

This RCBO is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

MPN
A9D02832