Schneider Electric A9D04810 — Residual Current Breakers (RCCB/RCBO)

A9D04810 Acti9 iC60H RCBO, 10 A, B Curve, 30 mA, 10 kA

MPNA9D04810
Active

Schneider Electric Acti9 iC60H RCBO, A9D04810, 1P+Ns, 10 A rated at 50 °C, B curve, 30 mA earth-leakage sensitivity, 10 kA Icn breaking capacity at 240 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D04810 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D04810 — Electrical Ratings
ParameterValue
Rated current (In)10 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D04810 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D04810 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D04810 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D04810 — Approvals
ParameterValue
StandardsIEC 61009-2-2 IEC 61009-1

Product details

It protects a single outgoing circuit (1P + Ns) against both overload/short-circuit and earth leakage. The 77.5 mm depth fits enclosures with typical back-panel clearance. Rated for TN earthing systems per IEC 61009-1 and IEC 61009-2-2, the RCBO is designed for AC networks at 50 Hz. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit response. Limitation class 3 means it restricts let-through energy under fault conditions, reducing stress on downstream wiring and loads.

Screw-clamp terminals accept rigid conductors up to 25 mm² on the top (line) side and 16 mm² on the bottom (load) side. Flexible conductors are limited to 16 mm² top and 10 mm² bottom. Strip lengths are 14 mm for the top and 13 mm for the bottom — maintaining these prevents whiskers under the clamp that could compromise the connection. Rated for 5000 electrical cycles and 20000 mechanical cycles.

MPN
A9D04810