Skip to main content
Schneider Electric A9D04816 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D04816 Acti9 iC60 RCBO, 16 A, Curve B,

MPNA9D04816
Active

Schneider Electric Acti9 iC60H RCBO, order code A9D04816, 1P+Ns, 16 A rated at 50 °C, Curve B, 30 mA earth-leakage sensitivity, 10 kA Icn at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D04816 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D04816 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D04816 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D04816 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D04816 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D04816 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It packs a 16 A thermal-magnetic MCB and a 30 mA earth-leakage module into a single 18 mm wide DIN-rail module, saving a slot over separate devices. The 1P+Ns pole configuration means it switches the live conductor only and monitors the neutral for leakage; the neutral stays connected through the device. Integrated earth-leakage protection at 30 mA sensitivity covers personnel protection against direct contact (per IEC 61009-1).

The 30 mA earth-leakage sensitivity is the standard threshold for personal protection in TN earthing systems — it's what you'd specify for socket-outlet circuits in residential or office distribution boards. The Curve B characteristic (3-5 In) means it holds through normal inrush from resistive loads but trips fast on a short circuit; don't use it for motor circuits or transformers where the inrush could nuisance-trip. The IP20/IP40 rating means it's protected against solid objects >12.5 mm (fingers) in normal use, and IP40 inside an enclosure; not for wet locations without a weatherproof cabinet.

Padlockable with a 4 mm diameter padlock for lockout/tagout. The toggle provides ON/OFF local indication. Depth is 77.5 mm, height 110 mm — check enclosure depth clearance before panel layout.

Frequently asked questions

Where can I buy A9D04816?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9D04816?

10,000 A Icn at 240 V AC, 50/60 Hz. That's the rated short-circuit capacity per IEC 61009-1 — the maximum fault current the device can safely interrupt.

What earth-leakage sensitivity does A9D04816 have?

30 mA, integrated into the RCBO. This is the standard sensitivity for personal protection against direct contact in TN earthing systems.

What standards does A9D04816 comply with?

IEC 61009-1 and IEC 61009-2-2 — the international standards for RCBOs covering both overcurrent and residual current protection.

MPN