Skip to main content
Schneider Electric A9D04840 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9D04840 Acti9 iC60H RCBO, 40 A, 30 mA, C

MPNA9D04840
Obsolete

Schneider Electric Acti9 iC60H RCBO, 1P + Ns, 40 A, 30 mA, curve B, 10 kA breaking capacity, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9D04840 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9D04840 — Electrical Ratings
ParameterValue
Rated current (In)40 A at 50 °C
Rated operational voltage (Ue)230/240 V AC 50/60 Hz
Poles description1P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D04840 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H RCBO
A9D04840 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules2
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid Screw clamp terminal (top) 1...16 mm² flexible Screw clamp terminal (bottom) 1...16 mm² rigid without cable end Screw clamp terminal (bottom) 1...10 mm² flexible
Wire stripping lengthPower circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 3.5 N.m top Power circuit: 2 N.m bottom
Width18 mm
Height110 mm
Depth77.5 mm
A9D04840 — Environmental
ParameterValue
Operating ambient temperature-15...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 IP40 (modular enclosure)
Relative humidity95 % at 55 °C
Tropicalisation2
A9D04840 — Approvals
ParameterValue
StandardsIEC 61009-1 IEC 61009-2-2

Product details

It protects a single-phase outgoing circuit against overload, short-circuit, and earth leakage, with a rated current of 40 A at 50 °C and an earth-leakage sensitivity of 30 mA. Torque the top connection to 3.5 N·m and the bottom to 2 N·m.

For a buyer sourcing this part, the paperwork is straightforward: the standards compliance covers most global markets, and the part carries the Schneider Electric brand with full traceability.

Integration notes

The module occupies 2 x 9 mm pitches (18 mm total width) on a DIN rail. Depth is 77.5 mm, height 110 mm. The toggle actuator provides ON/OFF local signalling and is padlockable with a 4 mm diameter padlock for lockout/tagout. The electrical durability is rated at 5,000 cycles, mechanical durability at 20,000 cycles — figures that reflect a typical panel-mounted distribution device rather than a high-cycling motor-switching role. The limitation class is 3, which limits let-through energy under fault conditions.

Frequently asked questions

What are the key ratings of the A9D04840?

Rated current 40 A at 50 °C, earth-leakage sensitivity 30 mA, curve B, breaking capacity 10 kA Icn at 240 V AC, thermal-magnetic trip, 1P + Ns poles.

Where can I buy the A9D04840 and how is it quoted?

We source and quote this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does the A9D04840 comply with?

It complies with IEC 61009-1 and IEC 61009-2-2, the international standards for residual current operated circuit-breakers with integral overcurrent protection.

MPN
A9D04840