Schneider Electric A9DC1910
MPNA9DC1910
Active
Residual current breaker with overcurrent protection (RCBO), Acti9 iC60H3, 3P+Ns, C Curve, 10A, 30mA, A type, 10000A
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Control type | Toggle |
| Network type | AC |
| Product or component type | Residual current breaker with overcurrent protection (RCBO) |
| Test button operating voltage | 260...457 V |
| Voltage | 500 V |
| [Ue] rated operational voltage | 400/415 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Icw] rated short-time withstand current | Icw: 250 A during 8/20 µs impulse withstand |
| Operating voltage for protection against earth-leakage | 150...457 V |
| Surge current | 250 A |
| Breaking capacity | 10000 A Icn at 400/415 V |
| Current | 10 A at 30 °C |
All specifications
| Parameter | Value |
|---|---|
| Residual current tripping technology | Voltage dependent |
| [Ics] rated service breaking capacity | 7500 A |
| Network frequency | 50/60 Hz |
| Poles description | 3P + Ns |
| Number of protected poles | 3 |
| IP degree of protection | IP20 |
| Mounting mode | Clip-on |
| Mounting support | DIN rail Chassis |
| Wire stripping length | Power circuit: 11 mm for bottom connection Power circuit: 14 mm for top connection |
| Connections - terminals | Screw clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible |
| Relative humidity | 95 % at 55 °C |
| Depth | 77.2 mm |
| Width | 54 mm |
| Color | White |
| Height | 112 mm |
| Product weight | 462 g |
| Electrical durability | 5000 cycles |
| Mechanical durability | 20000 cycles |
| Standards | AS/NZS 61009.1 IEC 61009-1 IEC 61009-2-2 |
| Range | Acti9 |
| Curve code | C |
| 9 mm pitches | 6 |
| Grid distance | 45 mm |
| Earthing system | TN |
| Tropicalisation | 2 |
| Limitation class | 3 |
| Local signalling | ON/OFF indication |
| Neutral position | Left |
| Device short name | iC60H3 RCBO |
| Tightening torque | Power circuit: 2.5 N.m top Power circuit: 2.5 N.m bottom |
| Trip unit technology | Thermal-magnetic |
| Earth-leakage protection | Integrated |
| Provision for padlocking | Padlockable with padlock Ø 4 mm Lead seal |
| Device location in system | Outgoer |
| Earth-leakage sensitivity | 30 mA |
| Suitability for isolation | Yes conforming to IEC 61009-1 |
| Circuit breaker application | Distribution |
| Locking options description | Handle sealable with cable diameter 1.4mm in OFF or ON position |
| Earth-leakage protection class | Type A |
| Ambient air temperature for storage | -25...70 °C |
| Earth-leakage protection time delay | Instantaneous |
| Ambient air temperature for operation | -5...60 °C |
| Comb busbar and distribution block compatibility | YES |
MPN