Skip to main content
Schneider Electric A9DF3616

Schneider Electric A9DF3616

MPNA9DF3616
Active

Residual current breaker with overcurrent protection (RCBO), Acti9 iCV40N, 1P+N, 16A, C curve, 6000A, A-SI type, 30mA

$52.43Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DF3616 key specifications
ParameterValue
Control typeToggle
Network typeAC
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Voltage400 V AC 50/60 Hz
[Ue] rated operational voltage230 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Current16 A
Residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Network frequency50/60 Hz
Poles description1P + N

All specifications

A9DF3616 additional specifications
ParameterValue
Number of protected poles1
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Mounting modeClip-on
Mounting supportDIN rail
Connection pitch9 mm between phase and neutral
Wire stripping length14 mm for top or bottom connection
Connections - terminalsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
Depth73 mm
Width36 mm
ColorWhite
Height85 mm
Electrical durability20000 cycles
Mechanical durability20000 cycles
StandardsEN/IEC 61009-2-1
RangeActi9
Curve codeC
9 mm pitches4
Quality labelsKEMA-KEUR RCM EAC VDE
Limitation class3 conforming to EN/IEC 61009-2-1
Local signallingON/OFF indication Fault indication
Neutral positionLeft
Device short nameiCV40N
Tightening torque2 N.m top or bottom
Device applicationDistribution
Overvoltage categoryIII conforming to IEC 60364
Trip unit technologyThermal-magnetic
Magnetic tripping limit5...10 x In
Earth-leakage protectionIntegrated
Device location in systemOutgoer
Earth-leakage sensitivity30 mA
Suitability for isolationYes conforming to EN/IEC 60947-2
Contact position indicatorYes
Locking options descriptionSealable Padlocking device
Electromagnetic compatibility8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1
Earth-leakage protection classType A-SI (Super Immunised)
Rated breaking and making capacityIdm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1 Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1
Ambient air temperature for storage-40...85 °C
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-25...60 °C
Comb busbar and distribution block compatibilityTop or bottom: tooth
MPN