Skip to main content
Schneider Electric A9DF3716 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DF3716 Acti9 iCV40 RCBO, 16 A, 30 mA, C

MPNA9DF3716
Active

Schneider Electric Acti9 iCV40 RCBO, A9DF3716, 3P+N, 16 A, C-curve, 30 mA earth leakage, 6 kA Icn at 400 V AC.

$267.25Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DF3716 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationFault indication ON/OFF indication
A9DF3716 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)400 V AC 50/60 Hz
Poles description3P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DF3716 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40N
A9DF3716 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules10
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width90 mm
Height93 mm
Depth73 mm
A9DF3716 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DF3716 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9DF3716 is an Acti9 iCV40 residual current circuit breaker with overcurrent protection (RCBO) — 3P+N, 16 A rated current, C-curve, 30 mA earth leakage sensitivity. Breaking capacity is 6 kA Icn at 400 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

The 16 A rating and C-curve (5–10× In magnetic trip) suit general-purpose lighting and socket-outlet circuits where inrush from small motors or capacitive loads is moderate — not for heavy motor starts where a D-curve would be needed. The 30 mA earth leakage sensitivity is the standard for personal protection against indirect contact in residential and commercial final circuits per IEC 60364. The limitation class 3 (EN/IEC 61009-2-1) means the let-through energy is low enough to allow downstream selectivity with a higher-rated upstream device — useful in multi-level distribution.

Clip-on DIN rail mount, 90 mm wide × 93 mm high × 73 mm deep — occupies 10 module pitches. Neutral is on the left. Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; tightening torque is 2 N·m. IP20 on the body, IP40 inside a modular enclosure. Mechanical and electrical durability both rated at 20,000 cycles.

Frequently asked questions

What is A9DF3716's breaking capacity?

6 kA Icn at 400 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

What is the earth leakage sensitivity of A9DF3716?

30 mA, integrated into the RCBO.

Where can I buy A9DF3716?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider Electric provide for A9DF3716?

The part carries VDE and EAC quality labels and conforms to EN/IEC 61009-2-1.

MPN