Skip to main content
Schneider Electric A9N19872

Schneider Electric A9N19872

MPNA9N19872
Obsolete

Acti9 DCP N Vigi - RCBO - 3P - 10A - C Curve - 6000A/10kA - 30mA - type A

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19872 key specifications
ParameterValue
Control typeToggle
Network typeAC
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Voltage500 V AC 50 Hz
[Ue] rated operational voltage220...240 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Breaking capacity10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-1
Current10 A
Residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Network frequency50 Hz
Poles description3P

All specifications

A9N19872 additional specifications
ParameterValue
Number of protected poles3
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Mounting modeClip-on
Mounting supportDIN rail
Wire stripping length12 mm for top or bottom connection
Connections - terminalsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible
Relative humidity95 % at 55 °C
Depth76 mm
Width54 mm
ColorWhite
Height85 mm
Electrical durability10000 cycles
Mechanical durability20000 cycles
StandardsEN/IEC 61009-2-1
RangeActi9
Curve codeC
9 mm pitches6
Tropicalisation2
Limitation class2
Local signallingON, OFF, fault trip
Device short nameDCP N Vigi
Tightening torque2 N.m top or bottom
Device applicationDistribution
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Magnetic tripping limit5...10 x In
Earth-leakage protectionIntegrated
Earth-leakage sensitivity30 mA
Suitability for isolationYes
Contact position indicatorYes
Locking options descriptionNon padlockable
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Earth-leakage protection classType A
Rated breaking and making capacityIdm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Earth-leakage protection time delayInstantaneous
Ambient air temperature for operation-25...40 °C
MPN
A9N19872