Schneider Electric A9R54263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R54263 Acti9 iID RCCB, 63A, 300mA, Type

MPNA9R54263
Obsolete

Schneider Electric Acti9 iID, RCCB, 2P, 63 A, 300 mA, Type A, voltage-independent, instantaneous, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9R54263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R54263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R54263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R54263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73.5 mm
A9R54263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R54263 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R54263 is a 2-pole Acti9 iID residual current circuit breaker (RCCB) rated for 63 A continuous load on a 220...240 V AC 50/60 Hz network. The tripping is voltage-independent and instantaneous, so it clears a ground fault without relying on the line voltage to power the trip coil, and it does so without intentional delay.

The 63 A [In] rated current sets the maximum continuous load the RCCB can carry without nuisance tripping — sized for a main incomer or sub-feed on a residential or light commercial distribution board. The 300 mA sensitivity is the earth-leakage trip threshold; it is a common choice for fire protection (rather than personnel protection, which typically uses 30 mA) and is often specified for circuits supplying fixed equipment where a lower sensitivity would cause unwanted trips from normal leakage. Type A detection covers the waveform shapes produced by single-phase rectifiers, so this unit is appropriate for circuits feeding electronics, IT equipment, or appliances with switch-mode supplies. Breaking capacity is rated at Idm 1500 A and Im 1500 A — the fault-clearing capability for residual and overcurrent faults respectively. The rated impulse withstand voltage of 6 kV (Uimp) and insulation voltage of 500 V AC (Ui) confirm the unit can handle typical transient overvoltages on a 230/400 V supply network without internal flashover. Mechanical durability is 20000 cycles, electrical durability (AC-1 resistive load) is 15000 cycles — these are the expected lifetimes under normal switching duty. The unit is designed for infrequent manual switching (toggle control) as a disconnecting means, not for repeated daily switching like a contactor.

Clip-on mounting to a DIN rail, 36 mm width (4 x 9 mm pitches), 91 mm height, 73.5 mm depth — fits standard modular enclosure cutouts. Neutral is on the left. Terminals accept 1...35 mm² rigid or 1...25 mm² flexible (with or without ferrule); tightening torque 3.5 N.m; strip length 14 mm. IP20 finger-safe on the front face, IP40 inside a modular enclosure. Pollution degree 3 (conductive or dry non-conductive pollution) — suitable for control panels in industrial environments where some dust and condensation are present.

Frequently asked questions

Where can I buy the A9R54263 and get a price?

The A9R54263 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm price and lead time.

What is the closest alternative to the A9R54263 in the Acti9 family?

Within the Acti9 iID range, the closest alternative would be a different sensitivity or current rating (e.g., a 40 A or 100 A variant, or a 30 mA version for personnel protection). The A9R54263 itself is the 63 A, 300 mA, Type A, 2P configuration — there is no pin-compatible substitute that matches all ratings exactly; select based on the required [In] and sensitivity.

What compliance documentation does Schneider provide for the A9R54263?

The A9R54263 is designed and tested to EN/IEC 61008-1 (the standard for residual current operated circuit-breakers without integral overcurrent protection). It carries CE marking for the European market. For specific documentation (declaration of conformity, RoHS, REACH), Schneider Electric provides these on request through their product documentation portal.

What is the depth of the A9R54263?

The depth is 73.5 mm (including the body and terminals). The width is 36 mm (4 modules), height is 91 mm.

MPN
A9R54263