Skip to main content
Schneider Electric A9R54440 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R54440 Acti9 iID RCCB, 40A, 300mA, 4P

MPNA9R54440
Obsolete

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 4P, 40 A, 300 mA, Type A, 380-415 V AC, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9R54440 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R54440 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R54440 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R54440 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R54440 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R54440 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R54440 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID range, rated at 40 A with 300 mA earth-leakage sensitivity. It operates on 380–415 V AC, 50/60 Hz networks, and provides Type A protection — covering sinusoidal AC residual currents and pulsating DC residual currents up to 6 mA, which is the typical waveform from rectifier loads like switched-mode power supplies and variable-speed drives. The RCCB is voltage-independent: it trips on residual current alone, without needing a separate power supply for the detection circuit. This makes it fail-safe against neutral loss scenarios where an electronic trip unit might not operate.

The 40 A rated current (In) defines the continuous load this RCCB can carry. It is intended for outgoing feeder protection in distribution boards. Rated operational voltage of 380–415 V AC covers most three-phase four-wire systems in Europe and Asia. The insulation voltage (Ui) is 500 V AC, meaning the internal clearances and creepage distances are designed for that voltage class — important for coordination with upstream switchgear. The impulse withstand voltage (Uimp) of 6 kV ensures the device survives transient surges common in industrial networks without internal flashover. Breaking and making capacity is rated at 1500 A (Idm and Im). For installations with higher fault currents, an upstream MCB or fuse must limit the let-through energy.

The 4-pole unit occupies 8 modules of 9 mm pitch (72 mm total width). Neutral is on the left-hand side — confirm the busbar or wiring order matches your board layout before termination.

Frequently asked questions

What is the A9R54440 rated current and earth-leakage sensitivity?

The A9R54440 is rated at 40 A (In) with a 300 mA earth-leakage sensitivity (Type A).

What standards does the A9R54440 comply with?

The A9R54440 complies with EN/IEC 61008-1, covering residual current operated circuit-breakers without integral overcurrent protection for household and similar uses.

MPN