Skip to main content
Schneider Electric A9R62263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R62263 Acti9 iID RCCB, 63A, 100mA, 2P

MPNA9R62263
Obsolete

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 63 A, 100 mA sensitivity, Type AC, DIN rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R62263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R62263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R62263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R62263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height96 mm
Depth74.5 mm
A9R62263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R62263 — Approvals
ParameterValue
StandardsGB 16916.21

Product details

It's rated 63 A continuous (In) with a 100 mA earth-leakage sensitivity, covering the standard Type AC waveform (sinusoidal AC residual currents). The 2-pole (2P) unit clips onto a DIN rail, occupying 36 mm of panel width, and is intended for outgoing feeder protection in distribution boards.

The 63 A rated current (In) sets the continuous load capacity — sized for a main incomer or sub-feed on a 230–240 V AC single-phase circuit. The 100 mA sensitivity is less sensitive than the common 30 mA type; it's chosen where a higher leakage threshold is acceptable (e.g., circuits without socket outlets, or where nuisance tripping from equipment leakage is a concern). The voltage-independent trip mechanism means the RCCB disconnects on earth leakage even if the line voltage is lost — a safety advantage over electronically tripped units. The instantaneous time delay provides no intentional delay; it trips within the standard RCCB response window, so it's not for selectivity with downstream delayed RCCBs unless coordinated by fault current magnitude. The insulation voltage (Ui) is 500 V AC, and the operational voltage (Ue) is 230–240 V AC, 50 Hz only.

Clip-on mounting to DIN rail — standard 35 mm rail. The 36 mm width occupies two 18 mm modular pitches (9 mm pitches: 4, so 36 mm total). Depth is 74.5 mm, height 96 mm. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible wire; tightening torque is 3.5 N·m top or bottom. Wire stripping length is 14 mm. The neutral position is left. IP20 finger protection — suitable for enclosed distribution boards; IP40 with the modular enclosure.

Frequently asked questions

What is A9R62263's rated current and earth-leakage sensitivity?

Rated current (In) is 63 A; earth-leakage sensitivity is 100 mA, Type AC.

What are the mounting dimensions of A9R62263?

Width 36 mm (2 modular pitches), height 96 mm, depth 74.5 mm. Clips onto standard 35 mm DIN rail.

Where can I buy A9R62263 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does A9R62263 carry?

The listed standard is GB 16916.21. The product is a Schneider Electric Acti9 iID RCCB; compliance documentation (RoHS, REACH, CE) is typically available from the manufacturer's product page for this range.

MPN