Schneider Electric A9R71240S — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R71240S Acti9 iID RCCB, 40 A, 30 mA, 2P

MPNA9R71240S
Active

Schneider Electric Acti9 iID, RCCB, 2P, 40 A, 30 mA, Type AC, 220-240 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R71240S — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R71240S — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R71240S — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R71240S — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73.5 mm
A9R71240S — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R71240S — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9R71240S is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID family, rated 40 A continuous and 30 mA earth-leakage sensitivity. The 30 mA trip threshold covers personnel protection (hand-to-ground fault paths) per IEC 60364. Voltage-independent tripping means the RCCB clears a ground fault even if the phase voltage collapses, which matters on circuits where the neutral might lift. The 1500 A making/breaking capacity (Idm/Im) handles the inrush from downstream MCBs without welding contacts.

Neutral on the left, line on the right — standard for Acti9 outgoing feeders. Terminals accept 1 to 35 mm² rigid or 1 to 25 mm² flexible (with or without ferrule); strip length 14 mm. Torque to 3.5 N·m. IP20 body, IP40 inside a modular enclosure. Padlocking option for lockout/tagout.

Frequently asked questions

What is the breaking capacity of A9R71240S?

Rated breaking and making capacity is 1500 A (Idm and Im) at 220–240 V AC, 50/60 Hz.

What standards does A9R71240S comply with?

It complies with EN/IEC 61008-1 and EN/IEC 61008-2-1 for residual current circuit breakers.

Where can I buy A9R71240S?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.