Skip to main content
Schneider Electric A9R71240 — Residual Current Breakers (RCCB/RCBO)

A9R71240 Acti9 iID RCCB, 40A 30mA Type AC, 2P

MPNA9R71240
Active

Schneider Electric Acti9 iID RCCB, A9R71240, 2P, 40 A rated, 30 mA sensitivity, Type AC, 220-240 V AC, DIN rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R71240 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R71240 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R71240 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R71240 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73.5 mm
A9R71240 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R71240 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The A9R71240 is a Schneider Electric Acti9 iID residual current circuit breaker (RCCB), 2-pole, rated 40 A with 30 mA earth-leakage sensitivity, Type AC. It protects against sinusoidal AC fault currents in residential and commercial final circuits, per EN/IEC 61008-1.

Terminals accept 1–35 mm² rigid or 1–25 mm² flexible (with or without ferrule); strip length is 14 mm, tighten to 3.5 N·m. IP20 rated on the body, IP40 inside a modular enclosure — suitable for dry indoor distribution boards.

Insulation voltage is 500 V AC. Impulse withstand voltage is 6 kV. The residual current tripping technology is voltage-independent — it operates without an external power source, so it still clears a ground fault even if the line voltage drops. The earth-leakage protection is instantaneous (no intentional time delay). Pollution degree 3 environment. Mechanical durability is 20,000 cycles; electrical durability is 15,000 cycles at AC-1 resistive load. The device is located as an outgoer in the distribution system.

Breaking and making capacity: Idm 1500 A, Im 1500 A. Electromagnetic compatibility: 8/20 µs impulse withstand at 250 A per EN/IEC 61008-1.

Frequently asked questions

Who supplies A9R71240 and how is it quoted for volume purchases?

The A9R71240 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is A9R71240's listed depth on this component line?

The A9R71240 has a depth of 73.5 mm.

What is A9R71240's listed range?

The A9R71240 belongs to the Schneider Electric Acti9 range, specifically the Acti9 iID series.

What compliance documentation does this brand provide for A9R71240?

The A9R71240 complies with EN/IEC 61008-1 and carries a CE mark. The manufacturer provides the standard declaration and compliance documentation.

MPN