Skip to main content
Schneider Electric A9R71263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R71263 Acti9 iID RCCB, 63 A, 30 mA, Typ

MPNA9R71263
Obsolete

Schneider Electric Acti9 iID, RCCB, 2P, 63 A, 30 mA, Type AC, 220-240 V AC, clip-on DIN rail.

$49.13Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R71263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R71263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R71263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R71263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73.5 mm
A9R71263 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R71263 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R71263 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, 63 A device with 30 mA earth-leakage sensitivity, Type AC, rated for 220...240 V AC at 50/60 Hz.

The 63 A [In] rated current sets the continuous load capacity — sized for a main incomer or sub-feed on a 63 A circuit. The 30 mA sensitivity catches leakage to earth at a level that protects against direct-contact shock (the standard threshold for personal protection per IEC 60364). The voltage-independent tripping technology means the RCCB detects and clears earth faults even if the phase voltage collapses, a useful safety margin on a degraded supply. Rated impulse withstand voltage [Uimp] is 6 kV, and the device carries an 8/20 µs impulse withstand of 250 A per EN/IEC 61008-1 — it will ride through typical surge events without nuisance tripping.

This RCCB is an outgoer device — it sits downstream of the main switch or breaker, protecting a branch circuit. The clip-on DIN-rail mount and 36 mm width (4 modules) fit standard modular enclosures. IP20 body rating means it is intended for a closed panel or distribution board, not for wet or outdoor locations.

Frequently asked questions

How do I get current pricing and availability for A9R71263?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through our independent distribution network.

What is A9R71263's listed depth?

The depth is 73.5 mm.

What is A9R71263's listed range?

It belongs to the Schneider Electric Acti9 range, specifically the Acti9 iID series of RCCBs.

What compliance documentation does this brand provide for A9R71263?

The device is certified to EN/IEC 61008-1. Standard compliance documentation (declaration of conformity, CE marking) is available from the manufacturer for this active catalogue item.