Schneider Electric A9Z31263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Z31263 Acti9 iID RCCB, 63A 30mA Type A-

MPNA9Z31263
Active

Schneider Electric Acti9 iID, RCCB, 2P, 63 A, 30 mA, Type A-SI, 220-240 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Z31263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9Z31263 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9Z31263 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9Z31263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsDouble terminal front 1...35 mm² rigid Double terminal front 1...25 mm² flexible Double terminal front 1...25 mm² flexible with ferrule Double terminal back 1...25 mm² rigid Double terminal back 1...16 mm² flexible Double terminal back 1...16 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height91 mm
Depth73 mm
A9Z31263 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9Z31263 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9Z31263 is an Acti9 iID 2-pole residual current circuit breaker (RCCB) rated for 63 A continuous load with 30 mA earth-leakage sensitivity. It is a Type A-SI (Super Immunised) device, meaning it handles pulsed DC fault currents from single-phase rectified loads and resists nuisance tripping from high-frequency leakage typical of VFDs, UPS systems, and LED drivers. The voltage-independent tripping mechanism means it clears a ground fault even if the phase voltage collapses — no auxiliary supply needed. Rated operational voltage is 220...240 V AC at 50/60 Hz, and it clips onto a standard DIN rail, occupying 4 x 9 mm pitches (36 mm wide).

The conditional short-circuit rating is 10 kA — the RCCB can be installed downstream of a 10 kA-rated upstream protective device (MCB or fuse) without being destroyed by a through-fault. In a domestic or light commercial panel fed by a 10 kA-rated main breaker, the 10 kA conditional rating is the number that governs coordination. The IP20 body is touch-safe but not splash-proof; the IP40 rating applies when installed in a modular enclosure.

The 36 mm width occupies 4 module pitches — plan your rail fill accordingly. Terminals accept up to 35 mm² rigid or 25 mm² flexible conductors, with a wire stripping length of 14 mm and a tightening torque of 3.5 N·m. Double-terminal design allows daisy-chaining the feed-through without a separate distribution block. Neutral is on the left. The toggle control provides a clear contact-position indicator and accepts a padlocking device for lockout/tagout.

MPN
A9Z31263