Schneider Electric C063N32AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C063N32AFM ComPacT NS new generation, 630

MPNC063N32AFM
Obsolete

Schneider Electric ComPacT NS new generation, C063N32AFM, 3P molded case circuit breaker, 630 A at 50 °C, MicroLogic 2.0 A electronic trip unit, 85 kA Icu at 240 V AC.

$2,915.40Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C063N32AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C063N32AFM — Ratings
ParameterValue
Rated current (In)630 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C063N32AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C063N32AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C063N32AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C063N32AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C063N32AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C063N32AFM is a fixed-mount, manually operated 3-pole molded case circuit breaker from the ComPacT NS new generation family, rated 630 A at 50 °C with a MicroLogic 2.0 A electronic trip unit. That 630 A figure is the trip-unit rating, not a frame maximum — the breaker is sized for distribution feeders or large motor branch circuits pulling that continuous current. The 85 kA Icu at 240 V AC and 50 kA Icu at 415 V AC (per IEC 60947-2) tell you the interrupting capacity at those voltages; for a 415 V distribution panel, 50 kA Icu means it can safely clear a fault up to that level without upstream devices needing to trip. The MicroLogic 2.0 A provides L (long-time overload) and I (instantaneous short-circuit) protection, with an ammeter display and 20-minute thermal memory for re-close coordination after a trip.

Mounts fixed to a backplate via the 70 mm connection pitch — no DIN-rail adapter, so plan for bolt-down installation inside a distribution cabinet. IP40 enclosure protection keeps dust out but isn't rated for washdown; install in a clean, dry indoor panel. The IK07 impact rating means it survives a 2 J hammer blow — fine for a locked electrical room, not for a production floor where tools get dropped on it regularly.

Frequently asked questions

What is C063N32AFM's breaking capacity at 415 V AC?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2.

How do I get current pricing and availability for C063N32AFM?

Submit an RFQ against this order code; pricing and stock are confirmed at quote time through independent distribution channels.

What compliance documentation does this brand provide for C063N32AFM?

The breaker is designed and tested to EN/IEC 60947-2, with pollution degree 3 and overvoltage category III ratings. Specific RoHS/REACH/UL declarations should be requested at quote time from the supplier.

MPN