Skip to main content
Schneider Electric C080S4FM — Miniature Circuit Breakers (MCB)

C080S4FM ComPacT NS Switch Disconnector, 800 A, 4P, Manual

MPNC080S4FM
Active

Schneider Electric ComPacT NS new generation, basic frame, C080S4FM, 4P, fixed, manually operated, 800 A AC-23A, 690 V AC, IEC 60947-3.

$1,329.21Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C080S4FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product/component typeBasic frame
Device applicationDistribution
C080S4FM — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-3
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-3
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-3
Network type (AC/DC)AC
Network frequency50/60 Hz
C080S4FM — Protection
ParameterValue
Suitability for isolationYes conforming to IEC 60947-3
Electrical durability (cycles)2000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-3
Mechanical durability (cycles)10000 cycles conforming to IEC 60947-3
C080S4FM — Mechanical
ParameterValue
Mounting modeFixed
Control typeManually operated
Contact position indicatorYes
Width327 mm
Height280 mm
Depth147 mm
C080S4FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-3
C080S4FM — Approvals
ParameterValue
StandardsIEC 60947-3

Product details

Panel integration — fixed mount, front connections, 70 mm pitch

The C080S4FM: Fixed mounting with front connections on both the line and load side. The 70 mm connection pitch matches standard busbar systems and cable-lug spacing for 800 A class gear. Dimensions are 327 mm wide by 280 mm high by 147 mm deep — allow for the front-access gland plate and bending radius of 240 mm² or 300 MCM cable. IK07 impact resistance means it survives a moderate tool drop during panel work.

Withstand and making capacity — selectivity headroom

Rated short-time withstand current (Icw) is 25 kA for 0.5 seconds, and 4 kA for 20 seconds — the longer duration rating matters for downstream coordination studies where the switch must ride through a delayed upstream breaker trip. Impulse withstand voltage (Uimp) is 8 kV, giving clearance for surge environments without external arrestors. The switch is suitability-for-isolation marked per IEC 60947-3, meaning you can use it as a visible-break-equivalent disconnecting means in a distribution panel.

The C080S4FM is an active, current-production part.

Frequently asked questions

Where can I buy the C080S4FM?

The C080S4FM is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does the 800 A AC-23A rating mean for motor loads?

AC-23A is the switch-disconnector category for motor loads and inductive circuits. The 800 A rating holds across the full voltage range up to 690 V, meaning it can switch motor feeders up to that current without derating for inrush.

What compliance standards does the C080S4FM meet?

Designed and tested to IEC 60947-3. Pollution degree 3, IP40, IK07, and suitability for isolation are all certified under that standard.

MPN