Skip to main content
Schneider Electric C10B3TM100C — Miniature Circuit Breakers (MCB)

C10B3TM100C ComPacT NSX100B 100A 3P Circuit Breaker, 25kA 41

MPNC10B3TM100C
Active

Schneider Electric ComPacT NSX series, NSX100B, 3-pole thermal-magnetic circuit breaker, 100 A, 25 kA Icu at 415 V AC, toggle control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10B3TM100C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10B3TM100C — Ratings
ParameterValue
Rated current (In)100 A at 50 °C
Poles configuration3P
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10B3TM100C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10B3TM100C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10B3TM100C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10B3TM100C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10B3TM100C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C10B3TM100C is a ComPacT NSX100B 3-pole thermal-magnetic MCCB rated 100 A at 50 °C. The TM-D trip unit gives fixed thermal (overload) and magnetic (short-circuit) protection — no interchangeable rating plugs, so the 100 A frame is the setting. Breaking capacity steps down as voltage climbs: 40 kA at 240 V, 25 kA at 415 V, 20 kA at 440 V, 15 kA at 500 V. For a 400 V panel with an available fault current of 22 kA, this breaker fits. For a 480 V system, the 15 kA Icu at 500 V is the relevant limit — check your SCCR study before committing the BOM line. The 3-pole version (3P) protects all three phases; the 3D protected-poles description confirms all three poles have trip elements.

Deployment context

Mounts on a backplate — not DIN-rail — so plan for a panel cutout or mounting plate. The 105 mm width, 161 mm height, and 86 mm depth fit standard MCCB footprints; the 35 mm connection pitch matches common busbar and lug spacing. IP40 protection means it's suitable for indoor, dry enclosures — no washdown or outdoor duty without an additional enclosure. Horizontal or vertical mounting is allowed; flat on the back is the standard orientation.

Electrical durability and power dissipation

Rated for 50,000 mechanical cycles and 30,000 electrical cycles at 440 V In. That's a solid duty cycle for a panel main or feeder breaker — not a switching device, but it handles regular load-break operations without accelerated wear.

Frequently asked questions

What are the key ratings of C10B3TM100C?

100 A rated current at 50 °C, 3-pole thermal-magnetic trip (TM-D), breaking capacity of 25 kA Icu at 415 V AC, and compliance with IEC 60947-2.

MPN
C10B3TM100C