C10F3TM025C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10F3TM025C — Ratings
ParameterValue
Rated current (In)25 A at 50 °C
Poles configuration3P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10F3TM025C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10F3TM025C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10F3TM025C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10F3TM025C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10F3TM025C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C10F3TM025C is a ComPacT NSX100F moulded-case circuit breaker with a 25 A TM-D thermal-magnetic trip unit, 3-pole, rated for distribution duty per EN/IEC 60947-2. The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection in one block — no electronic adjustments, no add-on modules. The 25 A rating at 50 °C sets the continuous current limit; the breaker carries 36 kA Icu at 380/415 V AC and 85 kA at 220/240 V AC, which means it can interrupt faults up to that level on a 415 V distribution bus without welding or rupturing. This is the figure that determines whether the breaker coordinates with upstream gear in a selective scheme.

Mounting and panel integration constraints

Mounts on a backplate, not a DIN rail — the 105 mm width, 161 mm height, and 86 mm depth need a cut-out and bolt-down clearance typical of panelboard or switchboard builds. The 35 mm connection pitch and front-facing terminals mean busbar or cable terminations stay accessible from the front; no rear-access panel design required. IK07 impact resistance handles accidental tool strikes during commissioning.

Frequently asked questions

What is the breaking capacity of the C10F3TM025C at 415 V?

36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. At 440 V it is 35 kA; at 220/240 V it is 85 kA. The 36 kA figure is the one to use for a standard 415 V distribution board coordination study.

What compliance documentation does Schneider provide for the C10F3TM025C?

The breaker is certified to EN/IEC 60947-2 and is suitable for isolation per that standard. The IP40 and IK07 ratings are tested per IEC 60529 and IEC 62262 respectively. Pollution degree 3 per IEC 60664-1 means it is rated for industrial environments with conductive pollution. RoHS and REACH declarations are standard Schneider documentation available on request.

MPN
C10F3TM025C