Schneider Electric C10H3TM016 — Miniature Circuit Breakers (MCB)

Schneider Electric C10H3TM016 ComPacT NSX100H, 16A, 70kA 415

MPNC10H3TM016
Active

Schneider Electric ComPacT NSX, NSX100H, circuit breaker, 3P, 16 A at 40 °C, thermal-magnetic TM-D trip unit, 70 kA breaking capacity at 415 V AC, IEC 60947-2.

$251.64 – $558.52Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10H3TM016 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10H3TM016 — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration3P
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10H3TM016 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10H3TM016 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10H3TM016 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10H3TM016 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10H3TM016 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The TM-D trip unit gives you thermal protection for overloads (L) and magnetic protection for short circuits (I). No earth-leakage module onboard, so if you need ground-fault protection, you'll add a Vigi add-on or external relay. The breaker itself is rated for isolation per EN/IEC 60947-2, meaning you can safely use it as a disconnecting means with visible contact indication.

At 240 V AC it's 100 kA Icu; at 480 V AC it's 65 kA (per UL 60947-4-1); at 600 V AC it drops to 10 kA. If your service entrance is 480 V, this 65 kA rating still gives you headroom for most secondary distribution. At 690 V (10 kA) it's mainly for motor circuits with limited fault current. The breaker is Category A (no intentional short-time delay), so it's a standard instantaneous trip device.

For a line-down spare or a BOM freeze, this is a straight drop-in: 3-pole, 16 A, thermal-magnetic, front-connected, backplate-mounted. No firmware, no configuration, no software download — just torque the lugs and close the cover. The mechanical durability of 50,000 cycles and electrical durability of 30,000 cycles at rated current (440 V In) mean it'll outlast most panel refreshes.

It mounts flat on a backplate — no DIN rail, so you'll need panel-mounting screws or a mounting bracket. The front-connect terminals (both line and load) make wiring straightforward in a standard enclosure. IP40 front face means it's splash-resistant from the front but not sealed for washdown; keep it inside a panel. Power dissipation is 2.92 W per pole.

Frequently asked questions

What is C10H3TM016's breaking capacity at 415 V AC?

70 kA Icu at 380/415 V AC per IEC 60947-2. That's the H breaking class — enough for most low-voltage distribution panels without needing an upstream current-limiting fuse.

What compliance documentation does this brand provide for C10H3TM016?

The breaker is certified to EN/IEC 60947-2 and carries UL 60947-4-1 ratings for the North American market. It's suitable for isolation per IEC 60947-2. The manufacturer provides a declaration of conformity; specific RoHS/REACH declarations are available on request through the RFQ process.