Schneider Electric C10R3TM063 — Miniature Circuit Breakers (MCB)

Schneider C10R3TM063 ComPacT NSX MCCB, 63 A, 200 kA Icu

MPNC10R3TM063
Active

Schneider Electric ComPacT NSX, new generation C10R3TM063 molded case circuit breaker, 3-pole, 63 A, 200 kA Icu at 690 V AC, thermal-magnetic TM-D trip unit, fixed mount, toggle control, IEC 60947-2.

$10.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jun 2026

Specifications

C10R3TM063 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10R3TM063 — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration3P
Breaking capacity200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)200 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10R3TM063 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C10R3TM063 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10R3TM063 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10R3TM063 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10R3TM063 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Overview

The TM-D trip unit is fixed at 63 A, so the breaker is selected for a specific load current; it is not field-adjustable like an Micrologic electronic trip.

Compared to the C10F3TM025 (NSX100F frame, 25 A, 85 kA Icu), the C10R3TM063 doubles the interrupting capacity to 200 kA and more than doubles the continuous rating to 63 A, making it the correct choice for high-fault distribution rather than low-current branch protection.

MPN
C10R3TM063