Schneider Electric C11E4TM063L — Miniature Circuit Breakers (MCB)

Schneider Electric C11E4TM063L ComPacT NSXm 63A 4P MCCB, 16k

MPNC11E4TM063L
Active

Schneider Electric ComPacT NSXm, 63 A, 4P, thermal-magnetic MCCB, 16 kA at 415 V AC, grey (RAL 7016).

$281.65Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E4TM063L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E4TM063L — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E4TM063L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11E4TM063L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11E4TM063L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E4TM063L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E4TM063L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
C11E4TM063L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

63 A 4P MCCB for distribution panels

The 63 A rating at 40 °C sets the continuous current limit for the branch circuit it protects — size the upstream feeder and downstream load conductors accordingly.

At 108 mm wide (12 module pitches of 9 mm), 137 mm high, and 80 mm deep, this breaker fits a standard backplate mount in a distribution board. The front-facing Everlink terminals accept 2.5–95 mm² rigid or stranded aluminium/copper, or 2.5–70 mm² flexible copper — one lug per pole, no adapter needed for the larger cable sizes common on a 63 A feed. IP40 front face and IK07 impact resistance are adequate for enclosed panel use; the breaker is not rated for washdown environments. The toggle control and flag indicator (green for auxiliary contact presence) give clear local status. Neutral is on the left, connections are front-to-front, and the breaker can be mounted horizontally or vertically flat on the backplate — useful when laying out a tight enclosure.

Isolation and coordination

The breaker is certified for isolation per IEC 60947-2 (suitability for isolation: yes), meaning it provides a visible break and meets the creepage/clearance distances required to safely isolate a circuit for maintenance. The 20,000-cycle electrical endurance at rated current (In) and 20,000-cycle mechanical endurance give a service life consistent with panel-mounted distribution breakers — not a switching device for frequent motor starts.

Frequently asked questions

Where can I buy C11E4TM063L and how do I get a price?

The C11E4TM063L is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is C11E4TM063L's breaking capacity?

The C11E4TM063L has a breaking capacity of 16 kA at 415 V AC (performance level E), which is the maximum fault current it can safely interrupt at that voltage. For lower fault-current scenarios, the same breaker still applies — the 16 kA rating is the ceiling, not the floor.

What compliance standards does C11E4TM063L meet?

The C11E4TM063L is certified to EN/IEC 60947-2 for low-voltage switchgear and controlgear. It is also suitable for isolation per that standard, and carries pollution degree 3 and overvoltage category III ratings per IEC 60664-1.

MPN
C11E4TM063L