Schneider Electric C11E4TM100L — Miniature Circuit Breakers (MCB)

Schneider Electric C11E4TM100L ComPacT NSXm MCCB, 100 A, 16

MPNC11E4TM100L
Active

Schneider Electric ComPacT NSXm, C11E4TM100L, 4P MCCB, 100 A at 40 °C, 16 kA at 415 V AC, thermal-magnetic TM-D trip unit, grey (RAL 7016).

$287.27Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11E4TM100L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11E4TM100L — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11E4TM100L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11E4TM100L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11E4TM100L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11E4TM100L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11E4TM100L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11E4TM100L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

This is a Category A breaker (no intentional short-time delay), so it is not designed for selectivity with downstream breakers in a cascaded scheme — coordinate it as the main or branch breaker in a radial distribution.

At 108 mm wide × 137 mm high × 80 mm deep, it occupies 12 module pitches of 9 mm — plan your DIN-rail or panel cut-out accordingly. Front connections (both upside and downside) accept Everlink lug terminals: 2.5…95 mm² rigid or stranded aluminium/copper, or 2.5…70 mm² flexible copper. The 35 mm connection pitch (27 mm without spreaders) matches standard busbar systems. The flag indicator (green) shows presence of auxiliary contacts, useful during commissioning to verify contact state without removing the cover.

The breaker carries no integrated earth-leakage protection; if ground-fault detection is required, specify an external residual-current device or a different trip unit variant. Electrical durability is 20,000 cycles at rated current (440 V, In/2) and 10,000 cycles at full In — adequate for distribution duty but not for frequent switching applications.

Frequently asked questions

What is the breaking capacity of C11E4TM100L?

Performance level E: 16 kA at 415 V AC. This is the maximum short-circuit current the breaker can safely interrupt under those conditions.

Where can I buy C11E4TM100L and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What compliance documentation does Schneider provide for C11E4TM100L?

The breaker is certified to EN/IEC 60947-2 and carries suitability for isolation per that standard. Overvoltage category III and pollution degree 3 per IEC 60664-1 are documented. RoHS/REACH declarations are available from Schneider Electric on request.

MPN
C11E4TM100L