Schneider Electric C11F3TM032L — Miniature Circuit Breakers (MCB)

Schneider C11F3TM032L ComPacT NSXm 3P 32A TM-D, 36 kA

MPNC11F3TM032L
Active

Schneider Electric ComPacT NSXm, circuit breaker, 3P, 32 A, TM-D trip unit, 36 kA at 415 V AC, grey (RAL 7016).

$167.94 – $254.36Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11F3TM032L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11F3TM032L — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11F3TM032L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11F3TM032L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C11F3TM032L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11F3TM032L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11F3TM032L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
C11F3TM032L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What it is and what it does

The C11F3TM032L is a Schneider Electric ComPacT NSXm moulded-case circuit breaker, 3-pole, with a 32 A thermal-magnetic TM-D trip unit. It's rated 36 kA at 415 V AC — that's the interrupting capacity at the panel's line side, so it clears a bolted fault up to that level without welding its contacts or venting arc gas into the enclosure. The TM-D trip gives you fixed thermal and magnetic protection: the thermal element handles overloads (slow curve), the magnetic element handles short-circuits (instantaneous). It's built to EN/IEC 60947-2, the standard for industrial MCCBs, and it's listed as suitable for isolation — meaning you can use it as a visible-break disconnect downstream of the main breaker.

Where it fits in the panel

Mounts flat on a backplate — no DIN rail required, though it does occupy 9 module pitches at 81 mm wide. The front-facing Everlink lugs accept 2.5 to 95 mm² rigid copper or aluminium, or 2.5 to 70 mm² flexible copper. That's a wide wire range for a 32 A breaker, handy when you're feeding a long run with voltage-drop upsizing. Connection pitch is 35 mm with spreaders, 27 mm without — so if you're landing parallel feeds, the spreaders give you room for the lug wrench. IP40 front face, IK07 impact rating: fine for a clean indoor panel, but not for washdown zones.

Frequently asked questions

Where can I buy C11F3TM032L and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What standards does C11F3TM032L comply with?

It complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear. It is also suitable for isolation per that standard.

What is the interrupting rating of C11F3TM032L?

The performance level is F, which corresponds to 36 kA at 415 V AC. That's the maximum fault current it can safely interrupt at that voltage.