Schneider Electric C11F6TM016L — Miniature Circuit Breakers (MCB)

Schneider Electric C11F6TM016L ComPacT NSXm 4P 16A 36kA MCCB

MPNC11F6TM016L
Active

Schneider Electric ComPacT NSXm, C11F6TM016L, 4P, 16 A at 40 °C, 36 kA at 415 V AC, thermal-magnetic TM-D trip unit, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11F6TM016L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11F6TM016L — Ratings
ParameterValue
Rated current (In)16 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11F6TM016L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11F6TM016L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11F6TM016L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11F6TM016L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11F6TM016L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
C11F6TM016L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The TM-D trip unit combines a thermal bimetal for overload protection (inverse-time curve) and a magnetic coil for short-circuit instantaneous trip. This is a Category A breaker — no intentional short-time delay, so it trips fast on fault.

Deployment context

Mounts on a backplate in any orientation — horizontal, vertical, or flat on the back. The 108 mm width occupies 12 module pitches on a 9 mm grid. Front connections top and bottom accept Everlink lugs: 2.5 to 95 mm² rigid or stranded aluminium/copper, or 2.5 to 70 mm² flexible copper. That is a generous wire range for a 16 A breaker — useful when pulling larger conductors for voltage drop on long runs. IP40 front face and IK07 impact rating make it suitable for indoor panel installation where tools or panels may bump the cover.

Frequently asked questions

What is the breaking capacity of C11F6TM016L?

36 kA at 415 V AC, which is the F performance level per Schneider's ComPacT NSXm range.

What standards does this MCCB comply with?

EN/IEC 60947-2 for low-voltage switchgear and controlgear. Also complies with IEC 60664-1 for pollution degree 3 and IEC 60529 for IP40 protection.

What wire sizes does the Everlink terminal accept?

One Everlink lug per pole accepts 2.5 to 95 mm² rigid or stranded aluminium/copper, and 2.5 to 70 mm² flexible copper.