Schneider Electric C11N4TM050B — Miniature Circuit Breakers (MCB)

C11N4TM050B ComPacT NSXm 4P 50A TM-D MCCB, 50 kA 415V

MPNC11N4TM050B
Active

Schneider Electric ComPacT NSXm, 4P 50 A thermal-magnetic MCCB, 50 kA at 415 V AC, IEC 60947-2, grey (RAL 7016).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11N4TM050B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11N4TM050B — Ratings
ParameterValue
Rated current (In)50 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11N4TM050B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11N4TM050B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11N4TM050B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11N4TM050B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11N4TM050B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11N4TM050B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What it is and what the ratings mean

The Schneider Electric C11N4TM050B is a ComPacT NSXm 4-pole moulded-case circuit breaker rated 50 A at 40 °C with a TM-D thermal-magnetic trip unit. The 50 kA at 415 V AC breaking capacity (performance level N) means it can safely interrupt a fault current up to that level without upstream fuses or breakers needing to clear it — a key figure for panel SCCR compliance. The 4P configuration (four protected poles) makes it suitable for three-phase plus neutral distribution where the neutral needs overcurrent protection, common in commercial and light industrial switchboards.

Standards and approvals

Designed and tested to EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear — specifically the circuit-breaker section covering overload and short-circuit protection. The suitability-for-isolation marking (IEC 60947-2) confirms it provides a visible air gap when open, so it can serve as a disconnecting means in a panel without a separate isolator. Pollution degree 3 per IEC 60664-1 means it is rated for conductive pollution in controlled environments (typical of most enclosed switchboards). Overvoltage category III places it in the fixed-installation class, downstream of the main distribution board. IP40 front face keeps tools and fingers out; IK07 impact resistance handles accidental knocks during maintenance.

Mounting and integration

Mounts flat on a backplate (horizontal or vertical) at 9 mm pitches (12 modules wide). Front connection top and bottom accepts compression lugs or busbars — no DIN-rail clip, so plan for direct panel mounting with a 35 mm pitch between phases (27 mm without spreaders). The grey RAL 7016 housing is standard for Schneider's ComPacT range. Neutral is on the left; the toggle control gives clear ON/OFF indication, and a green flag signals presence of auxiliary contacts when fitted.

Frequently asked questions

What are the key ratings for C11N4TM050B?

Rated 50 A at 40 °C with a thermal-magnetic TM-D trip unit, 4 poles, breaking capacity 50 kA at 415 V AC (performance level N), suitable for isolation per IEC 60947-2.

How do I get current pricing and availability for C11N4TM050B?

Submit an RFQ — the part is sourced to order through independent distribution, with current pricing and stock confirmed at quote time.

What compliance documentation does Schneider provide for C11N4TM050B?

The breaker is certified to EN/IEC 60947-2 and carries IP40, IK07, pollution degree 3, and overvoltage category III ratings. For RoHS/REACH declarations, refer to the manufacturer's compliance portal using the order code.