Schneider Electric C12E3TM125B — Miniature Circuit Breakers (MCB)

Schneider Electric C12E3TM125B ComPacT NSXm, 125 A, 16 kA

MPNC12E3TM125B
Obsolete

Schneider Electric ComPacT NSXm, circuit breaker, 125 A at 40 °C, 3P, 16 kA at 415 V AC, thermal-magnetic trip unit TM-D, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C12E3TM125B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C12E3TM125B — Ratings
ParameterValue
Rated current (In)125 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C12E3TM125B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C12E3TM125B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C12E3TM125B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C12E3TM125B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C12E3TM125B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 16 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C12E3TM125B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Above that, derate per the thermal curve in the datasheet. The 3-pole configuration (3P) covers three-phase loads. The TM-D trip unit is fixed, non-interchangeable, so what you order is what you get — no field-swap of trip curves.

Mounts on a backplate (not DIN rail) — the 9-module pitch at 81 mm width and 137 mm height fits standard distribution board cutouts. Connection is front-face on both line and load sides, using compression lugs or busbars. The 35 mm connection pitch with spreaders (27 mm without) matches common busbar systems. IP40 front-of-panel protection means it is splash-resistant from the front but not sealed — keep it inside the enclosure, not in a washdown zone. The grey RAL 7016 colour is the standard Schneider panel aesthetic. The flag indicator (green) shows auxiliary contact status at a glance.

Frequently asked questions

What is the breaking capacity of C12E3TM125B?

Performance level E: 16 kA at 415 V AC, per the IEC 60947-2 standard. This is the maximum fault current the breaker can safely interrupt at that voltage.

What standards does the C12E3TM125B comply with?

It is designed and tested to EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear. It is suitable for isolation per that same standard. Pollution degree 3 (IEC 60664-1) and overvoltage category III apply.

Where can I buy the C12E3TM125B?

This part is sourced and quoted to order through our independent distribution network. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
C12E3TM125B