Skip to main content
Schneider Electric C1642B160 — Miniature Circuit Breakers (MCB)

Schneider Electric C1642B160 MicroLogic 2.2 AB Trip Unit, 16

MPNC1642B160
Obsolete

Schneider Electric ComPacT NSX160/250, MicroLogic 2.2 AB electronic trip unit, 160 A, 4P, LSoI protection, special applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C1642B160 — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationSpecial application
C1642B160 — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C1642B160 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
C1642B160 — Mechanical
ParameterValue
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C1642B160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1642B160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C1642B160 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range90...160 A
Trip unit protection functionsLSoI

Product details

What this trip unit does

The C1642B160 is a MicroLogic 2.2 AB electronic trip unit rated 160 A at 40 °C, designed for the ComPacT NSX160/250 range. It provides LSoI protection — long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I) — with adjustable long-time pickup from 90 to 160 A and short-time pickup from 1.5 to 10 x Ir. Fixed instantaneous pickup is set at 1600 A.

Rated operational voltage is 690 V AC 50/60 Hz, so it works in standard 400 V and 480 V distribution panels without derating.

Deployment context

This trip unit mounts into a ComPacT NSX160 or NSX250 circuit breaker — fixed-mount, 4-pole, neutral left. The electronic trip technology gives you adjustable curves and a flashing green LED for ready status, plus red/orange LEDs at 105% and 90% Ir to flag overload conditions without opening the panel.

Frequently asked questions

What is C1642B160's listed range and standards?

The C1642B160 is part of the Schneider Electric ComPacT NSX100...250 range and complies with EN/IEC 60947-2.

Where can I buy C1642B160?

The C1642B160 is obsolete but available through our independent supply channel — submit an RFQ for current pricing and availability.

MPN
C1642B160