Schneider Electric C1642G160 — Miniature Circuit Breakers (MCB)

C1642G160 MicroLogic 2.2 G Trip Unit, ComPacT NSX, 160 A, Ob

MPNC1642G160
Obsolete

Schneider Electric ComPacT NSX series, MicroLogic 2.2 G electronic trip unit, 160 A, 4-pole, generator protection, EN/IEC 60947-2.

$656.26Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C1642G160 — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationGenerator
C1642G160 — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C1642G160 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
C1642G160 — Mechanical
ParameterValue
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C1642G160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1642G160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C1642G160 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range63...160 A
Trip unit protection functionsLSoI

Product details

The C1642G160 is a MicroLogic 2.2 G electronic trip unit from the Schneider Electric ComPacT NSX100...250 range, designed specifically for generator protection in AC networks at 50/60 Hz. Rated 160 A at 40 °C with a 4-pole configuration (3D + N/2, 4D, or 3D neutral protection selectable), it provides LSoI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I). The long-time pickup (Ir) is adjustable from 63 to 160 A across nine settings, while the short-time pickup (Isd) adjusts from 1.5 to 9 x Ir. Instantaneous pickup (Ii) is fixed at 2400 A.

Generator protection specifics

The 'G' suffix in MicroLogic 2.2 G indicates generator protection tuning. Local signaling includes a flashing green LED for ready-to-operate, a red LED at 105% Ir for overload, and an orange LED at 90% Ir for pre-alarm — useful for commissioning and fault isolation without opening the panel.

The C1642G160 is classified as obsolete per the manufacturer's lifecycle status. No official successor order code is listed in the manufacturer's records.

Installation and environment

Fixed-mount design for ComPacT NSX circuit breaker frames. Pollution degree 3 per IEC 60947-1 means it tolerates conductive pollution in industrial control panels — typical for factory-floor environments without climate control.

Frequently asked questions

What is the C1642G160 used for?

It is an electronic trip unit for generator protection in ComPacT NSX160/250 circuit breakers, providing LSoI protection (long-time, short-time with fixed delay, instantaneous) at 160 A, 690 V AC.

What standards does the C1642G160 comply with?

It complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear circuit breakers.

Where can I buy the C1642G160?

As an obsolete part, the C1642G160 is sourced through independent distribution channels. It is quoted to order against an RFQ, with availability and current pricing confirmed at quote time.

What is the difference between the C1642G160 and a standard MicroLogic 2.2 trip unit?

The 'G' designation means this trip unit is tuned for generator protection, including a 20-minute thermal memory that matches generator cool-down characteristics — a standard feeder trip unit uses a shorter thermal reset profile.