Schneider Electric C164TM160D — Miniature Circuit Breakers (MCB)

C164TM160D ComPacT NSX DC Trip Unit, 160 A, 4P 4D, Active

MPNC164TM160D
Active

Schneider ComPacT NSX DC trip unit, TM-D thermal-magnetic, 160 A rating, 4P 4D, 750 V DC, EN/IEC 60947-2.

$159.74 – $218.97Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C164TM160D — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250 DC
Product/component typeTrip unit
Device applicationDistribution
C164TM160D — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)750 V DC
Network type (AC/DC)DC
C164TM160D — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
C164TM160D — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C164TM160D — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C164TM160D — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C164TM160D is a thermal-magnetic trip unit for the ComPacT NSX100...250 DC range, rated 160 A at 40 °C with 4 protected poles (4D) on a 4-pole frame. It protects DC distribution circuits per EN/IEC 60947-2, with a fixed instantaneous pickup at 1250 A and an adjustable long-time pickup from 0.7 to 1.0 x In. The 750 V DC rated operational voltage means it handles the full DC bus voltage in common industrial battery banks, UPS outputs, or DC distribution panels — not just the lower 125 V or 250 V tiers. The LI protection profile — thermal overload (L) and magnetic short-circuit (I) — is the standard for DC branch circuits where earth-leakage detection is handled separately or not required. The fixed instantaneous trip at 1250 A (7.8 x In) provides a defined short-circuit threshold; no field adjustment means fewer commissioning variables but also no tuning around nuisance trips on capacitor inrush or motor starting in DC drives.

The trip unit mounts into a fixed ComPacT NSX DC circuit breaker frame. IP40 enclosure protection suits general-purpose indoor panels; no additional sealing is needed for standard control rooms or electrical rooms. Class II double-insulation construction simplifies grounding — no separate protective earth conductor required on the trip unit itself.

Frequently asked questions

What is C164TM160D's listed range and standards?

The C164TM160D belongs to the Schneider ComPacT NSX100...250 DC range and complies with EN/IEC 60947-2 for DC circuit-breaker performance.

Where can I buy C164TM160D and how is it quoted?

The C164TM160D is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for C164TM160D?

The trip unit is designed to EN/IEC 60947-2 and carries IP40 protection per IEC 60529. Specific RoHS, REACH, or UL documentation should be requested at quote time.