Schneider Electric C163TM125C — Miniature Circuit Breakers (MCB)

Schneider Electric C163TM125C ComPacT NSX Trip Unit, 125 A,

MPNC163TM125C
Active

Schneider Electric ComPacT NSX, TM-D trip unit, thermal-magnetic, 125 A at 50 °C, 3 poles 3D, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C163TM125C — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationDistribution
C163TM125C — Ratings
ParameterValue
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz 750 V DC
Network type (AC/DC)AC DC
Network frequency50/60 Hz
C163TM125C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
C163TM125C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C163TM125C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C163TM125C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

It provides LI protection — thermal overload (L) and magnetic short-circuit (I) — for distribution applications in AC or DC networks. Rated 125 A at 50 °C, it fits a 3-pole 3D breaker with fixed mounting. The instantaneous pickup is fixed at 1250 A (10× In), and the long-time pickup is adjustable from 0.7 to 1× In. That means you can dial the overload threshold down to 87.5 A if the load requires it, without changing the trip unit. Rated operational voltage is 690 V AC (50/60 Hz) and 750 V DC, so it handles standard 480Y/277 V and 600 V panels with headroom, and can be used in DC bus applications up to 750 V.

This is a trip unit, not a complete breaker — it installs into a ComPacT NSX160 or NSX250 fixed-mount circuit breaker. The TM-D unit has no earth-leakage protection built in. If you need ground-fault detection, you'll need a separate Vigi module or an electronic trip unit with that function. The 3D pole configuration protects all three phases; the neutral is unprotected unless you add a 4-pole breaker.

No second-source cross-reference exists within the same frame — the TM-D is the standard thermal-magnetic option for NSX160/250.

Frequently asked questions

What is C163TM125C's listed range and standards?

It belongs to the ComPacT NSX100...250 range and complies with EN/IEC 60947-2 for circuit-breaker performance and safety.

What are the key ratings of C163TM125C?

Rated 125 A at 50 °C, 690 V AC / 750 V DC, with a fixed instantaneous pickup of 1250 A and adjustable long-time pickup from 0.7 to 1× In. It provides LI (thermal-magnetic) protection for 3-pole distribution applications.

Where can I buy C163TM125C?

This trip unit is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.