Skip to main content
Schneider Electric C16B3TM080 — Miniature Circuit Breakers (MCB)

Schneider Electric C16B3TM080 ComPacT NSX160B 80A 3P 25kA 41

MPNC16B3TM080
Obsolete

Schneider Electric ComPacT NSX, NSX160B, circuit breaker, 80 A, 3P, TM-D trip unit, 25 kA Icu at 415 V AC, IP40.

$185.65Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16B3TM080 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16B3TM080 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration3P
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16B3TM080 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16B3TM080 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16B3TM080 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16B3TM080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16B3TM080 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C16B3TM080 is a ComPacT NSX160B moulded-case circuit breaker with a thermal-magnetic TM-D trip unit, rated 80 A at 40 °C, three poles, and a breaking capacity of 25 kA Icu at 415 V AC (50/60 Hz) per IEC 60947-2. It is suitable for isolation per the same standard, meaning it can serve as a disconnecting means in a distribution panel when the handle is padlocked off.

At 240 V the breaker can interrupt 40 kA Icu, which covers high-fault service entrances in North American panels. The 20 kA Icu at 440 V and 15 kA at 500 V give headroom for 480 V delta systems common in motor control centres.

Mounts flat on a backplate in horizontal or vertical orientation. Front-facing connections on both line and load sides simplify busbar and cable routing in a panel. The 35 mm connection pitch matches standard DIN-rail terminal blocks for outgoing feeders.

Frequently asked questions

Where can I buy C16B3TM080 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the breaking capacity of C16B3TM080 at 415 V?

25 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2.

What standards does C16B3TM080 comply with?

It is certified to EN/IEC 60947-2, suitable for isolation per that standard, and rated for pollution degree 3 per IEC 60664-1.

MPN
C16B3TM080