Schneider Electric C16B3TM100C — Miniature Circuit Breakers (MCB)

Schneider Electric C16B3TM100C ComPacT NSX 100A 3P Circuit B

MPNC16B3TM100C
Active

Schneider Electric ComPacT NSX160B, 100 A, 3-pole thermal-magnetic circuit breaker, 25 kA Icu at 415 V AC, EN/IEC 60947-2, toggle control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16B3TM100C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16B3TM100C — Ratings
ParameterValue
Rated current (In)100 A at 50 °C
Poles configuration3P
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16B3TM100C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16B3TM100C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16B3TM100C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16B3TM100C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16B3TM100C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C16B3TM100C is a Schneider Electric ComPacT NSX160B frame circuit breaker, 3-pole, rated 100 A at 50 °C with a TM-D thermal-magnetic trip unit. It is designed for distribution applications in commercial and industrial panels, with a breaking capacity of 25 kA Icu at 415 V AC (40 kA at 240 V, 20 kA at 440 V, 15 kA at 500 V) per EN/IEC 60947-2. The toggle control and front-connect terminals suit standard backplate mounting — horizontal or vertical — with a 35 mm connection pitch.

The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection, adjustable on the magnetic threshold. At 100 A, power dissipation is 7.7 W per pole — factor that into enclosure thermal rise, especially in a multi-breaker lineup. IP40 front face means tools and fingers are protected; the back is open to the panel interior.

Integration and mounting notes

Front connection for both line and load sides. Electrical durability: 40,000 cycles at 440 V In/2, 20,000 at In, 15,000 at 690 V In/2, 7,500 at 690 V In. Mechanical durability: 40,000 cycles.

Frequently asked questions

Where can I buy C16B3TM100C and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing.

What standards does C16B3TM100C comply with?

It complies with EN/IEC 60947-2, pollution degree 3 per IEC 60664-1, and IP40 / IK07 protection. Suitability for isolation is confirmed per EN/IEC 60947-2.

What is the breaking capacity of C16B3TM100C at 415 V?

25 kA Icu at 380/415 V AC 50/60 Hz per EN/IEC 60947-2. At 240 V it is 40 kA, at 440 V it is 20 kA, at 500 V it is 15 kA.

MPN
C16B3TM100C