Schneider Electric C16F3TM100C — Miniature Circuit Breakers (MCB)

Schneider C16F3TM100C ComPacT NSX160F, 100A, 36kA 415V

MPNC16F3TM100C
Active

Schneider Electric ComPacT NSX160F, 3-pole MCCB, 100 A thermal-magnetic TM-D trip, 36 kA Icu at 415 V AC, toggle control, front connections.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16F3TM100C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16F3TM100C — Ratings
ParameterValue
Rated current (In)100 A at 50 °C
Poles configuration3P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16F3TM100C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16F3TM100C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16F3TM100C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16F3TM100C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16F3TM100C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection in one block. Set the thermal pickup at the 100 A rating; the magnetic pickup is fixed within the trip unit. This is a distribution-grade breaker (Category A utilisation) — no intentional short-time delay for selective coordination, so it trips instantaneously on fault currents above the magnetic threshold.

Mounts on a backplate (not DIN rail) — the 105 x 161 x 86 mm (W x H x D) footprint fits standard MCCB cutouts. Horizontal or vertical mounting is allowed; flat on the backplate. Power dissipation is 7.7 W per pole.

Isolation suitability is confirmed per that standard, so it can be used as a disconnecting means. The IP40 front face and IK07 mechanical impact rating are per IEC 60529 and IEC 62262 respectively.

Frequently asked questions

What is the breaking capacity of C16F3TM100C at 415 V?

The C16F3TM100C has a breaking capacity of 36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, designated as breaking capacity code F.

What standards does C16F3TM100C comply with?

The C16F3TM100C complies with EN/IEC 60947-2 for circuit-breakers, with isolation suitability confirmed. It also meets IEC 60529 (IP40), IEC 62262 (IK07), and IEC 60664-1 (pollution degree 3).

MPN
C16F3TM100C