Skip to main content
Schneider Electric C2547A250

Schneider Electric C2547A250

MPNC2547A250
Active

Trip unit MicroLogic 7.2 E AL for ComPacT NSX 250 circuit breakers, electronic, rating 250A, 4 poles 4d

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C2547A250 key specifications
ParameterValue
Display typeLCD display
Network typeAC
Protection typeL : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection
Range of productComPacT NSX100...250
Type of measurementEnergy meter
Product or component typeTrip unit
Long-time protection delay adjustment type trAdjustable
Short-time protection delay adjustment type tsdAdjustable
Short-time protection pick-up adjustment type isdAdjustable
Instantaneous protection pick-up adjustment type iiAdjustable
Earth-leakage protection sensitity adjustment type iδnAdjustable
Earth-leakage protection time delay adjustement type δtAdjustable

All specifications

C2547A250 additional specifications
ParameterValue
Long-time pick-up adjustment type ir (thermal protection)Adjustable 9 settings
[Ue] rated operational voltage440 V AC 50/60 Hz
Network frequency50/60 Hz
Poles description4P
Protected poles description3D + N/2 4D 3D
IP degree of protectionIP40 conforming to IEC 60529
Communication of dataMaximeters/minimeters Test reports Demand current and power Protection and alarm settings Instantaneous and demand values Time-stamped histories and event tables Energy metering Maintenance indicators Earth leakage current Power quality
Circuit breaker mounting modeFixed
Pollution degree3 conforming to IEC 60947-1
Electrical shock protection classClass II
StandardsEN/IEC 60947-2
RangeComPacT
Thermal memory20 minutes before and after tripping
Trip unit nameMicroLogic 7.2 E AL
Local signallingFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
Neutral positionLeft
Trip unit rating250 A at 40 °C
Device applicationDistribution
Trip unit technologyElectronic
Earth-leakage protectionIntegrated
Neutral protection settings0.5 x Ir (3D + N/2) 1 x Ir (4D) No protection (3D)
Earth-leakage protection classType A Class A
Trip unit protection functionsLSI
Zone selective interlocking ZSIWithout
Ambient air temperature for storage-40...85 °C
Ambient air temperature for operation-25...70 °C
Earth-leakage protection specific modeOFF using the IΔn rotary switch
[Tr] Long-Time protection delay adjustment range15...400 s at 1.5 x Ir 0.35...11 s at 7.2 x Ir 0.5...16 s at 6 x Ir
[Ir] long-time protection pick-up adjustment range100...250 A
[tsd] short-time protection delay adjustment range0...0.4 s I²t=off 0.1...0.4 s I²t=on
[Isd] short-time protection pick-up adjustment range1.5...10 x Ir
[Ii] instantaneous protection pick-up adjustment range1.5...12 x In
[δt] earth-leakage protection time delay adjustment range0 ms 60 ms 150 ms 500 ms 1 s
[IΔn] earth-leakage protection sensitivity adjustment range500 mA 0.03 A 0.1 A 0.3 A 0.5 A 1 A 3 A 5 A
MPN