Schneider Electric C2544B250

Schneider C2544B250 MicroLogic 4.2 AB Trip Unit, 250 A, 4P

MPN C2544B250
Active

Schneider Electric ComPacT NSX250, MicroLogic 4.2 AB electronic trip unit, 250 A at 40 °C, 4P, LSoIR + earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C2544B250 specifications
ParameterValue
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage440 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationSpecial application
Operating temperature-25...70 °C

Product details

The Schneider Electric C2544B250 is a MicroLogic 4.2 AB electronic trip unit for the ComPacT NSX100...250 range of molded-case circuit breakers. It is the programmable brain that sits inside the breaker frame, measuring current and deciding when to trip based on the protection curves you set. This is a 4-pole unit (4P) rated at 250 A at 40 °C, designed for AC networks at 50/60 Hz with a rated operational voltage of 440 V AC. The trip unit provides LSoIR protection: L for long-time overload, So for short-time short-circuit with a fixed delay, I for instantaneous short-circuit, and R for earth-leakage. The earth-leakage protection is integrated and Class A, with adjustable sensitivity (IΔn) and time delay (Δt). This makes the unit suitable for special applications requiring both overcurrent and ground-fault protection in a single device.

The long-time pick-up (Ir) is adjustable from 140 to 240 A, so you can fine-tune the overload threshold to match the downstream load without swapping the trip unit. The short-time pick-up (Isd) adjusts from 1.5 to 10 times Ir, giving you selectivity coordination with downstream breakers — a key parameter for panel builders designing a coordinated distribution system per IEC 60947-2. The instantaneous pick-up is fixed at 2880 A — that is the magnetic-only trip level for bolted faults. This matters for motor-starting applications where repeated starts can overheat the circuit.

This trip unit mounts into a ComPacT NSX250 fixed-mount breaker frame. The neutral position is left, and the protected poles can be configured as 3D + N/2, 4D, or 3D — meaning you can set the neutral protection to half the phase current, full current, or none, depending on the system grounding. The local signaling includes a flashing green LED for ready, red LED at 105% Ir for overload, orange at 90% Ir for pre-alarm, and a yellow indicator for residual current. These are visible through the breaker's transparent cover for quick status checks without opening the panel.