Schneider Electric C63V45E630 — Miniature Circuit Breakers (MCB)

C63V45E630 ComPacT NSX 630A MCCB, 85 kA at 500V AC

MPNC63V45E630
Active

Schneider Electric ComPacT NSX, NSX630HB1, 4P, 630 A at 40 °C, 85 kA Icu at 500 V AC, MicroLogic 5.3 E electronic trip unit, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C63V45E630 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C63V45E630 — Ratings
ParameterValue
Rated current (In)630 A at 40 °C
Poles configuration4P
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C63V45E630 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical durability (cycles)15000 cycles
C63V45E630 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C63V45E630 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C63V45E630 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C63V45E630 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range250...630 A
Trip unit protection functionsLSI

Product details

The C63V45E630 is a 4-pole ComPacT NSX molded case circuit breaker rated 630 A at 40 °C, built around the MicroLogic 5.3 E electronic trip unit. That trip unit gives you L (long-time overload), S (short-time short-circuit), and I (instantaneous) protection curves — the E designation means it includes energy metering as a native function, so you get power quality data, demand values, and time-stamped event logs without an add-on module. Breaking capacity sits at 85 kA Icu at 500 V AC (50/60 Hz), 80 kA at 525 V, and 75 kA at 690 V, all per IEC 60947-2. Mechanical durability is 15,000 cycles; electrical durability ranges from 8,000 cycles at 440 V at half rated current down to 2,000 cycles at 690 V at full In. For a distribution-grade MCCB in a fixed-backplate mount, those numbers align with a switchboard or main panel position where switching frequency is moderate.

Integration and mounting notes

Mounts flat on a backplate, either horizontal or vertical. Connection pitch is 45 mm, with both upside and downside connections on the front — no rear-access requirement, so it retrofits into existing panel layouts without re-terminating busbars. The toggle control and LCD display give local status: green flashing LED for ready-to-operate, red at 105% Ir for overload, orange at 90% Ir for pre-alarm.

Category A utilization (no intentional short-time delay for selectivity) means this breaker is designed for instantaneous or short-time protection coordinated with downstream devices, not for selective coordination with an upstream breaker requiring a deliberate delay. The MicroLogic 5.3 E's S protection (short-time) can be set with a delay, but the breaker itself is Category A — the delay is internal to the trip unit, not a mechanical feature. For full selectivity in a main-tie-main configuration, pair it with a Category B breaker upstream. Above 40 °C, or at altitudes above 2000 m, derating applies per the manufacturer's curves. The 0–2000 m range is no-derating; 2000–5000 m requires derating. Relative humidity up to 95% is within the operating envelope for indoor switchgear.

Frequently asked questions

Where can I buy C63V45E630?

The C63V45E630 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is C63V45E630's breaking capacity at 500 V AC?

85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2.

What does the MicroLogic 5.3 E trip unit protect against?

It provides L (long-time overload), S (short-time short-circuit), and I (instantaneous short-circuit) protection, plus energy metering.

What compliance standards does this MCCB meet?

It complies with EN/IEC 60947-2, pollution degree 3 per IEC 60664-1, and IK07 impact protection per IEC 62262.