Schneider Electric C63V42D630 — Miniature Circuit Breakers (MCB)

Schneider C63V42D630 ComPacT NSX 630A 4P MCCB, 85kA 500V

MPNC63V42D630
Active

Schneider Electric ComPacT NSX, C63V42D630, 4P MCCB, 630 A at 40 °C, MicroLogic 2.3 electronic trip unit, 85 kA Icu at 500 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C63V42D630 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C63V42D630 — Ratings
ParameterValue
Rated current (In)630 A at 40 °C
Poles configuration4P
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C63V42D630 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical durability (cycles)15000 cycles
C63V42D630 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C63V42D630 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C63V42D630 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C63V42D630 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range250...630 A
Trip unit protection functionsLSoI

Product details

The Schneider Electric C63V42D630 is a ComPacT NSX630HB1 moulded-case circuit breaker (MCCB) rated 630 A at 40 °C, 4 poles, with a MicroLogic 2.3 electronic trip unit. It delivers 85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2, making it a high-breaking-capacity choice for distribution panels where fault levels are substantial.

The 630 A trip rating at 40 °C sets the continuous current limit; above that ambient, derating applies per the manufacturer's curve. Overvoltage category III confirms it is intended for fixed-installation distribution boards, not downstream equipment. The IP40 front face and IK07 impact resistance suit it for enclosed panel mounting where occasional tool contact is expected. Mechanical durability is 15000 cycles. For a 630 A frame, these numbers are typical for distribution duty — not for frequent switching under load. If your application cycles the breaker daily under load, expect reduced electrical life.

The 185 mm width, 255 mm height, and 110 mm depth require a cutout or mounting footprint that fits standard 600 mm wide enclosures with room for cable bending radius. Front connections both upside and downside — plan for front-access gland plates. Neutral is on the left.

Frequently asked questions

What is C63V42D630's breaking capacity?

85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2, with 80 kA at 525 V and 75 kA at 660/690 V. The breaking capacity code is HB1.

What trip unit does C63V42D630 use?

A MicroLogic 2.3 electronic trip unit providing L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection. It has a 20-minute thermal memory.

What is the closest alternative to C63V42D630 in the same family?

Within the ComPacT NSX range, the closest peer is the same frame size (NSX630) with a different breaking capacity code — for example, an H1 (50 kA at 500 V) or H2 (70 kA) variant. The C63V42D630 is the HB1 (85 kA) version. The physical footprint, trip unit slot compatibility, and mounting are identical across these; the difference is only the interrupting rating. If your fault study shows 85 kA is not required, a lower-kA variant saves cost. If you need more, the NSX630 frame tops out at this HB1 level.