Skip to main content
Schneider Electric CR1F4004EZ7 — Contactors

TeSys F CR1F4004EZ7 Magnetic Latching Contactor, 4P, 400 A,

MPNCR1F4004EZ7
Active

Schneider Electric TeSys F CR1F magnetic latching contactor, 4 NO poles, 400 A rated operational current at 40 °C, 48 VDC low-consumption coil, active production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

CR1F4004EZ7 — Identification
ParameterValue
Product / component typeMagnetic latching contactor
Series / rangeTeSys
ApplicationResistive load Motor control
CR1F4004EZ7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)1000 V AC 25...200 Hz
Utilisation categoryAC-3 AC-1 AC-4
CR1F4004EZ7 — Contacts & Poles
ParameterValue
Pole configuration4P
CR1F4004EZ7 — Environmental
ParameterValue
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
CR1F4004EZ7 — Mechanical
ParameterValue
Width10.3 in (261 mm)
Height8.1 in (206 mm)
Depth8.6 in (219 mm)

Product details

Magnetic Latching Contactor for High-Current Motor Control

The CR1F4004EZ7 is a 4-pole magnetic latching contactor in the TeSys F range, designed for high-current motor switching and resistive load control. It carries a rated operational current of 400 A at 40 °C in AC-3 duty, and can handle motor loads up to 185 kW at 1000 V AC or 200 kW at 400 V AC. The latching mechanism holds the main contacts closed without continuous coil power, drawing 500 W only during the latching pulse and 70 W during unlatching—critical for applications where sustained coil dissipation is unacceptable or where the contactor must stay engaged during a control-power dropout.

Ratings That Define the Fit

The conventional free-air thermal current (Ith) is 500 A at 40 °C, meaning the main power path can carry that current continuously in open air without exceeding temperature rise limits. The rated insulation voltage (Ui) is 1000 V per IEC 60947-4 and BS 775, with an impulse withstand (Uimp) of 8 kV—this contactor is built for 1000 VAC line applications where surge coordination matters. Short-time withstand (Icw) is 3600 A for 1 second at 40 °C, giving the protection engineer headroom for selective coordination with upstream fuses or breakers.

Control Circuit and Coil Characteristics

The control circuit is 48 VDC low-consumption, with latching and unlatching voltage limits of 0.85 to 1.1 times Uc—so the coil must see at least 40.8 VDC to reliably latch, and no more than 52.8 VDC. Operating times are 40 to 75 ms for latching, 50 to 100 ms for unlatching. The latching coil draws 500 W DC during the pulse, then zero holding power; the unlatching coil draws 70 W DC. This low-consumption design suits battery-backed or UPS-fed control systems where sustained coil draw would drain reserves.

Physical Integration and Environment

Dimensions are 8.6 in (219 mm) deep, 10.3 in (261 mm) wide, and 8.1 in (206 mm) tall. The contactor is a panel-mount device with lug-ring terminal connections accepting two 150 mm² cables or two 30 x 5 mm bars per pole. Tightening torque is 35 N·m (309.8 lbf·in). Operating temperature range is -15 to 70 °C, storage -60 to 80 °C. The TH protective treatment indicates suitability for tropical/humid environments. Maximum operating rate is 120 cycles per hour at 40 °C.

Frequently asked questions

What is the closest pin-compatible alternative to CR1F4004EZ7 in the TeSys F family?

Within the TeSys F range, the CR1F4004EZ7 is a 4-pole magnetic latching contactor with 4 NO power poles. A standard (non-latching) equivalent would be the LC1F4004E7, which uses a continuous-duty coil instead of a latching mechanism. The mounting footprint and power-pole connections are identical, but the control circuit wiring differs—the latching version requires separate pulse signals for latch and unlatch, while the standard version needs continuous coil power.

What are the key ratings for this contactor?

Rated operational current (Ie) is 400 A at 40 °C in AC-3 duty. Conventional free-air thermal current (Ith) is 500 A. Motor power ranges from 185 kW at 1000 V to 110 kW at 220 V AC. Rated insulation voltage is 1000 V per IEC 60947-4. Control voltage is 48 VDC low-consumption latching.

What compliance documentation is available for CR1F4004EZ7?

The contactor carries IEC 60947-4, BS 775, and VDE 0110 group C approvals for insulation voltage. Schneider Electric provides RoHS and REACH declarations, as well as UL/CSA certifications, through their documentation portal.

MPN
CR1F4004EZ7