Schneider Electric CR1F5004N7 — Contactors

Schneider TeSys F CR1F5004N7 Magnetic Latching Contactor, 50

MPNCR1F5004N7
Obsolete

Schneider Electric TeSys F CR1F5004N7, magnetic latching contactor, 4-pole, 500 A rated operational current, 415 V AC 50/60 Hz coil, 335 kW motor power at 690 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

CR1F5004N7 — Identification
ParameterValue
Product / component typeMagnetic latching contactor
Series / rangeTeSys
ApplicationResistive load Motor control
CR1F5004N7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)1000 V AC 25...200 Hz
Utilisation categoryAC-4 AC-1 AC-3
CR1F5004N7 — Contacts & Poles
ParameterValue
Pole configuration4P
CR1F5004N7 — Environmental
ParameterValue
IP degree of protectionIP20 front face IEC 60529
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
CR1F5004N7 — Approvals
ParameterValue
StandardsIEC 60947-4 NF C 63-110 BS 5424 VDE 0660 JEM 1038
CR1F5004N7 — Mechanical
ParameterValue
Width11.3 in (288 mm)
Height9.4 in (238 mm)
Depth9.1 in (232 mm)

Product details

Magnetic Latching Contactor for Heavy Motor Control

The Schneider Electric CR1F5004N7 is a TeSys F magnetic latching contactor with 4 normally open power poles, rated for 500 A operational current (AC-3 duty) and capable of switching motor loads up to 335 kW at 690 V AC 50/60 Hz. The magnetic latching mechanism holds the contacts closed without continuous coil power — the 415 V AC coil draws 1800 VA during the latching pulse, then only 13 VA for unlatching. This makes it suited for applications where sustained coil power is undesirable or where a power loss must not drop out the load.

The 500 A rating at <= 440 V AC under AC-4 category means this contactor handles the severe inrush and plugging duty of reversing or jogging motor loads — not just steady running. Mechanical durability is 1 Mcycles, reflecting the robust TeSys F frame.

Where It Belongs in the Panel

Mounts on a notched AM1-EC rail — the standard heavy-duty DIN rail for contactors this size. Front face carries IP20 protection per IEC 60529, so it's touch-safe in an enclosed panel but not for open washdown areas. Connections accept lugs, ring terminals up to 240 mm², or bars 40 x 5 mm, torqued to 309.8 lbf.in (35 N.m). The 9.1 in (232 mm) depth and 11.3 in (288 mm) width require generous cabinet space; plan for side clearance for arc-chamber venting and cable bending radius.

Frequently asked questions

What is the control voltage for this contactor?

The control circuit voltage is 415 V AC 50/60 Hz. Latching and unlatching both operate within 0.85...1.1 Uc limits.

What standards does the CR1F5004N7 comply with?

It complies with IEC 60947-4, NF C 63-110, BS 5424, VDE 0660, and JEM 1038. Rated insulation voltage is 1000 V per IEC 60947-4 and VDE 0110 group C.

What is the breaking capacity?

Rated breaking capacity is 5000 A at 220...440 V, 4500 A at 500 V, 3560 A at 660/690 V, and 2500 A at 1000 V for the power circuit.

What is the closest alternative in the TeSys F family?

Within the TeSys F range, variants differ by coil voltage and pole configuration. The CR1F5004N7 uses a 415 V AC coil and 4 NO poles. A unit with a different coil voltage (e.g., 110 V or 230 V) or a different pole count (3-pole) would be a different order code. Select based on your control voltage and number of switched phases.