Schneider Electric CR1F6304U7 — Contactors

TeSys F CR1F6304U7 Magnetic Latching Contactor, 630 A, 450 k

MPNCR1F6304U7
Active

Schneider Electric TeSys F series, CR1F6304U7 magnetic latching contactor, 4-pole, 630 A rated operational current, 450 kW motor power at 1000 V AC, 240 V AC control coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

CR1F6304U7 — Identification
ParameterValue
Product / component typeMagnetic latching contactor
Series / rangeTeSys
ApplicationResistive load Motor control
CR1F6304U7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)1000 V AC 25...200 Hz
Utilisation categoryAC-3 AC-4 AC-1
CR1F6304U7 — Contacts & Poles
ParameterValue
Pole configuration4P
CR1F6304U7 — Environmental
ParameterValue
IP degree of protectionIP20 front face IEC 60529
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
CR1F6304U7 — Approvals
ParameterValue
StandardsIEC 60947-4 VDE 0660 NF C 63-110 JEM 1038 BS 5424
CR1F6304U7 — Mechanical
ParameterValue
Width15.3 in (389 mm)
Height12.0 in (304 mm)
Depth10.04 in (255 mm)

Product details

It's designed for high-power motor control and resistive loads, with a motor power rating of 450 kW at 1000 V AC and 375 kW at 415 V AC. The utilisation categories cover AC-3 (squirrel-cage motors), AC-4 (plugging/inching), and AC-1 (non-inductive or slightly inductive loads), so it's suited for heavy-duty switching in industrial panels. The contactor also carries a rated breaking capacity of 3200 A at 1000 V, which is the fault-clearing capability it can handle without welding or damage.

Dimensions are 12.0 in (304 mm) high, 15.3 in (389 mm) wide, and 10.04 in (255 mm) deep — this is a large frame, so plan for adequate panel space and cable bending radius. Power connections are via two 60 x 5 mm bars per pole, torqued to 513.3 lbf·in (58 N·m). The control circuit is 240 V AC 50/60 Hz, with latching and unlatching limits of 0.85 to 1.1 times Uc. The coil draws 2300 VA during latching (about 9.6 A inrush) and 11 VA holding — but since it's a latching contactor, there's no holding current once latched; the coil is only energised during the transition.

The contactor is designed to IEC 60947-4, VDE 0660, NF C 63-110, JEM 1038, and BS 5424 — these are the key standards for contactors and motor-starters across European, German, French, Japanese, and UK markets. For North American installations, the UL/CSA motor power ratings are listed: 800 hp at 575-600 V, 600 hp at 460-480 V, and 300 hp at 220-240 V for three-phase motors. The rated insulation voltage is 1000 V per IEC 60947-4 and BS 775, with a VDE 0110 group C rating of 1500 V.

Frequently asked questions

What are the key ratings for the CR1F6304U7?

Rated operational current is 630 A (AC-3 duty), with a motor power rating of 450 kW at 1000 V AC. The control circuit voltage is 240 V AC 50/60 Hz. It is a 4-pole magnetic latching contactor in the TeSys F series.

What standards does the CR1F6304U7 comply with?

It complies with IEC 60947-4, VDE 0660, NF C 63-110, JEM 1038, and BS 5424. UL/CSA motor power ratings are also provided for North American installations.

What is the mounting requirement for this contactor?

It mounts on a notched AM1-EC rail, which is a specific Schneider profile — not a standard 35 mm DIN rail. The front face is IP20 rated.

MPN
CR1F6304U7