Skip to main content
Schneider Electric CR1F630Q7 — Contactors

Schneider TeSys F CR1F630Q7 Magnetic Latching Contactor, 630

MPNCR1F630Q7
Obsolete

Schneider Electric TeSys F series, CR1F630Q7 magnetic latching contactor, 3-pole (3 NO), 630 A rated operational current, 380 V AC 50/60 Hz coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

CR1F630Q7 — Identification
ParameterValue
Product / component typeMagnetic latching contactor
Series / rangeTeSys
ApplicationResistive load Motor control
CR1F630Q7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)1000 V AC 25...200 Hz
Utilisation categoryAC-4 AC-3 AC-1
CR1F630Q7 — Contacts & Poles
ParameterValue
Pole configuration3P
CR1F630Q7 — Environmental
ParameterValue
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTC
CR1F630Q7 — Mechanical
ParameterValue
Width12.2 in (309 mm)
Height12.0 in (304 mm)
Depth10.04 in (255 mm)

Product details

The CR1F630Q7: The 630 A rating is in AC-4 duty (plugging, inching, reversing motor starts), which is the most demanding switching category. For AC-3 (normal motor starts) or AC-1 (resistive loads), the contactor can handle higher currents — the same frame is rated for 1000 A thermally (Ith) at 50 Hz. The 335 kW motor power at 400 V AC (AC-4) gives a direct motor-sizing reference: this contactor handles a 335 kW motor under reversing or jogging duty on a 400 V line. Rated breaking capacity is 6300 A at 220...440 V, dropping to 3200 A at 1000 V. Short-time withstand current (Icw) is 5.05 kA for up to 10 seconds at 104 °F (40 °C). The associated fuse rating is 630 A aM or gG at up to 440 V, or 1000 A BS88 — important for coordination when sizing upstream protection. Insulation voltage is rated at 1000 V per IEC 60947-4 and BS 775, and 1500 V per VDE 0110 Group C.

Operating temperature range is -15 to 70 °C (5...158 °F). Storage range is -60 to 80 °C (-76...176 °F). Maximum operating rate is 120 cycles per hour at 104 °F (40 °C).

Coil and control circuit details

The control circuit is AC 50/60 Hz at 380 V nominal. Latching and unlatching both require 0.85 to 1.1 times Uc (323...418 V). Average consumption is 8 VA unlatching and 2100 VA latching — the latching inrush is substantial, so the control transformer must be sized for that peak. Power dissipation per pole is 48 W in AC-3 duty and 120 W in AC-1 duty; factor that into enclosure heat load calculations.

Frequently asked questions

What is the closest alternative to the CR1F630Q7 in the TeSys F family?

Within the TeSys F range, the CR1F630Q7 is the 630 A, 380 V AC coil variant. A different coil voltage (e.g., 220 V or 480 V AC) would be a different order code in the same frame size. There is no pin-compatible substitute with different ratings — the coil voltage and current rating define the variant.

What are the key specifications of the CR1F630Q7?

Key specs: 3-pole magnetic latching contactor, 630 A rated operational current (AC-4), 380 V AC 50/60 Hz coil, 335 kW motor power at 400 V AC (AC-4), rated insulation voltage 1000 V, rated breaking capacity 6300 A at 220...440 V, mechanical durability 1 million cycles.

What compliance documentation is available for the CR1F630Q7?

The contactor is rated per IEC 60947-4, IEC 60158-1, BS 775, and VDE 0110 Group C for insulation voltage. The evidence does not list RoHS, REACH, or UL specific declarations, but as a current-production Schneider TeSys F part, standard compliance documentation should be available through the manufacturer.

MPN