Schneider Electric CV1BF2F0ZF511 — Contactors

Schneider CV1BF2F0ZF511 TeSys B Contactor, 80 A AC-3, 110 VA

MPNCV1BF2F0ZF511
Active

Schneider Electric TeSys B series, CV1BF2F0ZF511 contactor, 2-pole, 80 A AC-3 rated operational current, 690 V AC, 110 V AC 50 Hz coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

CV1BF2F0ZF511 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive circuits, heating, lighting Motor
CV1BF2F0ZF511 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-1 AC-3
CV1BF2F0ZF511 — Contacts & Poles
ParameterValue
Pole configuration2P
CV1BF2F0ZF511 — Other specifications
ParameterValue
Device short nameCV1BF
Control circuit typeAC
Pole contact composition2 NO
Coil voltage110 V AC 50 Hz
Auxiliary contact composition1 NO + 1 NC
[Ie] rated operational current80 A AC for power circuit
Current rating code of contactorBF

Product details

The Schneider Electric CV1BF2F0ZF511 is a TeSys B series contactor, 2-pole normally open configuration, rated for 80 A in AC-3 duty at 690 V AC. That AC-3 rating means it's sized for switching squirrel-cage motors — starting, stopping, and running under load — not just resistive heating. The coil pulls in on 110 V AC at 50 Hz, a common control voltage in European and Asian panel designs.

The 80 A rated operational current is the AC-3 figure — the one that governs motor switching. For resistive loads (AC-1), the same contactor can carry more, but the AC-3 number is the one you size against your motor FLA. The 2-pole NO configuration is straightforward for single-phase motor or line switching; the built-in 1 NO + 1 NC auxiliary contact block handles feedback to the PLC or status indication without an add-on module.

The TeSys B form factor snaps onto DIN rail — standard 35 mm. The 2-pole body is compact, leaving room for auxiliary blocks or a thermal overload relay in the same rail segment. Coil inrush at 110 V AC is brief but needs to be within the PLC relay or control transformer rating; check the coil VA inrush against your output card's maximum per-channel current. The spring-cage terminals accept 0.2–2.5 mm² solid or ferruled stranded; strip to 8 mm for a clean connection.

Frequently asked questions

What is the utilisation category and what does it mean?

The contactor is rated for AC-1 (resistive loads like heating and lighting) and AC-3 (squirrel-cage motor starting and running). The 80 A figure is the AC-3 rating — the one to match against motor full-load amps. AC-1 capability is higher but the AC-3 number is the binding constraint for motor duty.

What control voltage does this contactor need?

The coil is rated 110 V AC at 50 Hz. It is an AC control circuit type. Verify your control transformer or PLC output matches this voltage and frequency.

What auxiliary contacts are built in?

The contactor includes 1 normally open and 1 normally closed auxiliary contact as standard. These are wired for status feedback or interlocking without an add-on block.