Skip to main content
Schneider Electric CV1BF2F0ZF522 — Contactors

Schneider TeSys CV1BF2F0ZF522 Contactor, 2P, 80 A, 110 VAC C

MPNCV1BF2F0ZF522
Active

Schneider Electric TeSys B contactor, CV1BF2F0ZF522, 2-pole, 80 A rated operational current, AC-3/AC-1, 110 V AC 50 Hz coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

CV1BF2F0ZF522 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive circuits, heating, lighting Motor
CV1BF2F0ZF522 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)690 V AC
Utilisation categoryAC-3 AC-1
CV1BF2F0ZF522 — Contacts & Poles
ParameterValue
Pole configuration2P
CV1BF2F0ZF522 — Other specifications
ParameterValue
Device short nameCV1BF
Control circuit typeAC
Pole contact composition2 NO
Coil voltage110 V AC 50 Hz
Auxiliary contact composition2 NO + 2 NC
[Ie] rated operational current80 A AC for power circuit
Current rating code of contactorBF

Product details

Part identity and ratings

The Schneider Electric TeSys B contactor CV1BF2F0ZF522 is a 2-pole (2 NO main poles) device rated for 80 A operational current in AC-3 duty at 690 V AC. The coil pulls in on 110 V AC at 50 Hz. It also carries an AC-1 utilisation category for resistive loads like heating and lighting circuits.

The 80 A AC-3 rating is the motor-switching current — it governs the largest three-phase induction motor this contactor can handle under starting and stopping duty. The 110 V AC coil is standard for North American control transformers; verify your control voltage matches before wiring.

Auxiliary contacts and integration

Built-in auxiliary contacts are 2 NO + 2 NC, enough for a holding circuit plus one feedback signal to a PLC input without an add-on block.

Frequently asked questions

What is the utilisation category and what does it mean?

Rated AC-3 (motor switching) and AC-1 (resistive). The AC-3 rating of 80 A is the motor duty current; the AC-1 rating covers resistive loads like heaters at a higher current level.

What control voltage does the coil require?

110 V AC at 50 Hz. Verify your control transformer output matches before installation.

How many auxiliary contacts are built in?

2 normally open and 2 normally closed auxiliary contacts are included on the contactor, sufficient for a holding circuit and one status feedback signal.

MPN
CV1BF2F0ZF522