Schneider Electric G12E4A20 — Miniature Circuit Breakers (MCB)

G12E4A20 GoPact MCCB 125 20A 4P TM-D, 15 kA at 415 V

MPNG12E4A20
Active

Schneider Electric GoPact MCCB 125, thermal-magnetic circuit breaker, G12E4A20, 4P, 20 A at 40 °C, 15 kA at 415 V AC, TM-D trip unit.

$108.98Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12E4A20 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12E4A20 — Ratings
ParameterValue
Rated current (In)20 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12E4A20 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12E4A20 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12E4A20 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12E4A20 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12E4A20 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12E4A20 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.8...1 x In
Trip unit protection functionsLI

Product details

The G12E4A20 is a fixed-mount GoPact MCCB 125 with a 20 A thermal-magnetic TM-D trip unit protecting four poles (4D). Rated 20 A at 40 °C and 15 kA breaking capacity at 380/415 V AC, it is sized for distribution duty in a 415 V AC 50/60 Hz panel. The TM-D trip unit gives LI protection: thermal L for overload (inverse-time, responds to sustained overcurrent) and magnetic I for short-circuit (instantaneous above a set threshold). This is a Category A breaker — no intentional short-time delay, so it trips fast on a hard fault. Use it in a distribution board where selectivity downstream is handled by smaller branch breakers, not by deliberate delay. The 440 V AC rated insulation voltage and isolation suitability per EN/IEC 60947-2 mean it can positively disconnect — show me the padlock provision on the toggle if you are using it for LOTO.

Backplate-mounted, fixed position. The 25 mm connection pitch and 100 mm width fit standard distribution board cutouts. IP20 finger-safe terminals — wire it in an enclosure rated for the environment.

Standards compliance

The isolation marking per EN/IEC 60947-2 is your evidence for a visible-break disconnect — if it's not locked, it's not safe, but this breaker is rated to be the isolation point.

Frequently asked questions

Who supplies G12E4A20 and how is it quoted for volume purchases?

The G12E4A20 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is G12E4A20's rated current and breaking capacity?

Rated 20 A at 40 °C with a 15 kA breaking capacity at 380/415 V AC, per EN/IEC 60947-2.